Chemistry |
RP/Anion-exchange |
Separation Mode |
Mixed mode |
Particle Substrate |
Hybrid |
pH Range Max |
10 pH |
Temperature Limits |
60 C |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
C18 AX |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
2.5 µm |
Endfitting Type |
Parker-style |
Pore Size |
95 Å |
Format |
Premier Column |
Surface Area |
270 |
System |
UHPLC, UPLC |
Particle Technology |
BEH |
Technique |
LC |
USP Classification |
L78 |
Inner Diameter |
2.1 mm |
Length |
50 mm |
Carbon Load |
17 % |
UNSPSC |
41115709 |
Brand |
Atlantis |
Product Type |
Columns |
Units per Package |
1 pk |
Atlantis Premier BEH C18 AX Column, 2.5 µm, 2.1 x 50 mm, 1/pk
Use the Atlantis Premier BEH C18 AX Column under reversed-phase conditions as it provides high retention for polar acidic analytes and delivers exceptional results. The analytical column's reversed-phase/anion-exchange mixed-mode chemistry is pH 2-10 stable. In addition to this, the lab equipment exhibits complementary selectivity to standard C18 stationary phases on the market, which is highly advantageous when developing methods.
The Atlantis PREMIER BEH C18 AX Column uses MaxPeakTM High-Performance Surfaces, which is a novel technology that has been specially engineered to improve analyte recovery, sensitivity, and reproducibility by eliminating analyte/surface interactions that can lead to sample losses. As a result of this, the Atlantis PREMIER BEH C18 AX Column is a reliable piece of lab equipmentthat not only provides solid, consistent analytical findings but is also extremely efficient, allowing you to prepare and use as many samples as you need.
The Atlantis Premier BEH C18 AX Column packing material is made in a cGMP, ISO 9001 certified plant using ultra-pure reagents, like the rest of Waters' lab equipment. In addition to this, each batch is chromatographically tested to confirm product quality, and the results are restricted to narrow specification ranges to ensure great, repeatable performance.
Every Atlantis Premier BEH C18 AX Column is independently tested, and in the column box or on the eCordTM Intelligent Chip, a Performance Chromatogram and Certificate of Batch Analysis are included. Each batch of packing material has its own Certificate of Analysis. The batch number, unbonded particle analysis, bonded particle analysis, and chromatographic results and conditions are all included in the certificate. The batch number, column serial number, USP tangent efficiency, USP tailing factor, retention factor, and chromatographic conditions are all included in the Performance Test Chromatogram for each particular column. It is recommended that these data should be stored for future reference. This way, Waters guarantees that the lab equipment that you receive from us is of the highest quality.
Store your samples and analytes in the LCMS Certified Clear Glass 12 x 32 mm Screw Neck Total Recovery Vial, with Cap and Preslit PTFE/Silicone Septum, 1 mL Volume, 100/pk.
Is There A Temperature Limit For The Atlantis Premier BEH C18 AX Column?
The Atlantis Premier BEH C18 AX Column, as listed here, demonstrates excellent performance within a maximum temperature limit of 60°C. It is crucial to adhere to this temperature restriction to ensure optimal column efficiency, peak resolution, and longevity. Operating the column within the specified temperature range guarantees reliable and accurate results for your chromatographic analyses.