Chemistry |
RP/Anion-exchange |
Separation Mode |
Mixed mode |
Particle Substrate |
Hybrid |
pH Range Max |
10 pH |
Temperature Limits |
60 C |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
C18 AX |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Parker-style |
Pore Size |
95 Å |
Format |
Premier Column |
Surface Area |
270 |
System |
HPLC |
Particle Technology |
BEH |
Technique |
LC |
USP Classification |
L78 |
Inner Diameter |
2.1 mm |
Length |
50 mm |
Carbon Load |
17 % |
UNSPSC |
41115709 |
Brand |
Atlantis |
Product Type |
Columns |
Units per Package |
1 pk |
Atlantis Premier BEH C18 AX VanGuard FIT Column, 5 µm, 2.1 x 50 mm, 1/pk
Under reversed phase circumstances, the Atlantis Premier BEH C18 AX Columns provide exceptional retention for polar acidic analytes. The reversed phase/anion-exchange mixed-mode chemistry is pH 2-10 stable and offers complementary selectivity to typical C18 stationary phases, which is advantageous when developing methods. The VanGuard FIT Column format is a guard-column design that is all-in-one, designed to eliminate dead volume and maximize column lifetime.
Use the Atlantis Premier BEH C18 AX VanGuard FIT Column to prevent the unwanted entrance of sample matrix or particles onto the column without interfering with the separation. The laboratory equipment was designed to enhance the operating lifetimes of analytical columns. It works in conjunction with the analytical column and can be easily replaced to restore separation performance and extend the analytical column's life.
The Atlantis Premier BEH C18 AX VanGuard FIT Column is a single item that connects directly to the inlet side of an Atlantis Column. The pre-column protects your column from dangerous contaminants and boosts and improves the analytical performance of the column by filtering out any chemical and particle pollutants that may be present in the mobile phase stream.
Since it is constructed from the same high-performance packing materials as the Atlantis Premier BEH C18 column, the Atlantis Premier BEH C18 AX VanGuard FIT Column is intended to work with the Atlantis Premier BEH C18 column. The Atlantis Premier BEH C18 AX VanGuard FIT Column is a vital piece of laboratory equipment that was specifically designed and produced for situations requiring greater capacity for biological fluid cleanup and/or temperature control.
Waters' complete product line can be seen on our website or in our brochure. The website allows you to shop for lab equipment as well as contact us with any questions. Compatible with the Atlantis Premier BEH C18 AX VanGuard FIT Column, we recommend checking out the Atlantis Premier BEH C18 AX VanGuard FIT Cartridge, 5 µm, 2.1 x 5 mm, 3/pk; Atlantis Premier BEH C18 AX cartridges work with the Atlantis Premier BEH C18 AX VanGuard FIT columns. The mixed mode reversed-phase/anion-exchange guard cartridges keep matrix and sample impurities out of the analytical column.
What Are The Atlantis Premier BEH C18 AX VanGuard FIT Column's Operating Limits?
To ensure optimal productivity and prolong the lifespan of the column, it is advisable to operate within or below the recommended maximum operating limits of the Atlantis Premier BEH C18 AX VanGuard FIT Column. This column offers a maximum pH range of 10pH, a temperature limit of 60°C, and a maximum pressure of 18,000 psi (1240 Bar). By staying within these limits, you can achieve efficient performance and enhance the longevity of the column.