Chemistry |
RP/Anion-exchange |
Separation Mode |
Mixed mode |
Particle Substrate |
Hybrid |
pH Range Max |
10 pH |
Temperature Limits |
60 C |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
C18 AX |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Parker-style |
Pore Size |
95 Å |
Format |
Premier Column |
Surface Area |
270 |
System |
HPLC |
Particle Technology |
BEH |
Technique |
LC |
USP Classification |
L78 |
Inner Diameter |
2.1 mm |
Length |
50 mm |
Carbon Load |
17 % |
UNSPSC |
41115709 |
Brand |
Atlantis |
Product Type |
Columns |
Units per Package |
1 pk |
Atlantis Premier BEH C18 AX Column, 5 µm, 2.1 x 50 mm, 1/pk
Scientists across the globe have been asking for a flexible reverse-phase method development column that promotes seamless method transfer, and the Atlantis Premier BEH C18 AX Column is here to satisfy that need. The mixed-mode C18 anion-exchange column chemistry makes this a stable, reliable choice to have in your lab’s toolkit. What’s more, that column chemistry provides complementary selectivity to C18 stationary phases, making it a top choice among LC-MS experts looking for that facet. Every Atlantis Premier Column has also earned the MaxPeak designation, which means it employs breakthrough technology to prevent losses in signal intensity caused by unwanted analyte-surface interactions. Add the Atlantis Premier BEH C18 AX Column to your lab’s procurement list today, or tell your lab manager that you want Atlantis Premier technology at your disposal.
To help boost retention of polar acidic compounds by 50%, all Atlantis Premier Columns combine incredible particle technology with MaxPeak High Performance Surface Technology. Together, these two features create a stable environment for your analyses and assays to flourish, all the while offering data reproducibility needed for method validation and development. Plus, thanks to the Ethylene-Bridged Hybrid (BEH) particle, maximum retention is always prioritized. Just look at the Atlantis Premier BEH C18 AX Column pH range and it’s easy to see why so many scientists choose this chromatography consumable over others.
Compare the anion-exchange column chemistry to traditional C18 options and it’s clear why scientists choose the Atlantis Premier BEH C18 AX Column over others. For one, it offers the separation performance and flexibility needed for method development, but it prioritizes retention of polar acidic compounds as well. That overwhelming stability is promoted by its max pH range, too.
Don’t need the Atlantis Premier BEH C18 AX Column but want the breakthrough tech offered by Atlantis Premier?
Shop Atlantis Premier Columns to find the right match for your assays. With Z-HILIC and BEH AX options to choose from, you’re sure to find the right tool to help you perform method development and carry out seamless method transfer when needed.
At Waters, it’s our passion to provide the instruments, equipment and resources that scientists need to be successful. From chromatography consumables to quality control reference materials, we have your lab’s procurement list completely covered. Shop for lab equipment now and spend more time working on your important assays.
What’s the Max Pressure Allowed by the Atlantis Premier BEH C18 AX Column?
The Atlantis Premier BEH C18 AX Column can operate under pressures of up to 18,000 psi.