Chemistry |
RP/Anion-exchange |
Separation Mode |
Mixed mode |
Particle Substrate |
Hybrid |
pH Range Max |
10 pH |
Temperature Limits |
60 C |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
C18 AX |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Parker-style |
Pore Size |
95 Å |
Format |
Premier Column |
Surface Area |
270 |
System |
HPLC |
Particle Technology |
BEH |
Technique |
LC |
USP Classification |
L78 |
Inner Diameter |
4.6 mm |
Length |
150 mm |
Carbon Load |
17 % |
UNSPSC |
41115709 |
Brand |
Atlantis |
Product Type |
Columns |
Units per Package |
1 pk |
Atlantis Premier BEH C18 AX VanGuard FIT Column, 5 µm, 4.6 x 150 mm, 1/pk
To prevent the unwanted introduction of sample matrix or particles onto the column without impairing the separation, use the Atlantis Premier BEH C18 AX VanGuard FIT Column. The laboratory equipment was created with the goal of extending the operational lifetimes of analytical columns. It operates in tandem with the analytical column and may be readily replaced to restore separation performance and extend the life of the analytical column.
Between the injector and the Atlantis Premier BEH C18 column, the Atlantis Premier BEH C18 AX VanGuard FIT Column is a form of protective lab equipment. It works by preventing chemical contaminants and suspended solids from reaching the analytical column, hence extending its life and increasing its reliability. Under reversed-phase circumstances, the Atlantis Premier BEH C18 AX Columns provide exceptional retention for polar acidic analytes. The mixed-mode chemistry of reversed-phase/anion exchange is stable from pH 2 to 10 and possesses complementary selectivity to typical C18 stationary phases, which is advantageous when developing techniques. The VanGuard FIT Column format is a guard-column design that reduces dead volume while increasing column longevity.
The Atlantis Premier BEH C18 AX VanGuard FIT Column is designed to operate with the Atlantis Premier BEH C18 column since it is made with the same high-performance packing materials as the Atlantis Premier BEH C18 column. The Atlantis Premier BEH C18 AX VanGuard FIT Column is a critical piece of lab equipment that was designed and manufactured specifically for circumstances when the higher capacity for biological fluid cleanup and/or temperature control is required.
The Atlantis Premier BEH C18 AX VanGuard FIT Column is a single unit that connects directly to an Atlantis Column's inlet side. By filtering out any chemical and particle pollutants that may be present in the mobile phase stream, the pre-column protects your column from dangerous contaminants and increases and improves the column's analytical performance.
Find the full offerings of Waters products from our website or through our brochure. The website enables you to shop for lab equipment, as well as to reach out with any queries you may have. We also recommend you to review the Atlantis Premier BEH C18 AX VanGuard FIT Cartridge, 5 µm, 3.9 x 5 mm, 3/pk; Atlantis Premier BEH C18 AX cartridges work with the Atlantis Premier BEH C18 AX VanGuard FIT columns. The mixed-mode reversed-phase/anion exchange guard cartridges protect the analytical column from matrix and sample contaminants.
What Are The Operating Limits Of The Atlantis Premier BEH C18 AX VanGuard FIT Column?
The Atlantis Premier BEH C18 AX VanGuard FIT Column has a max pH Range of 10pH, Temperature limit of 60 C, and can sustain a maximum pressure of 18,000 psi (or 1240 Bar); however, to ensure efficient productivity and longevity of the column, it is recommended to operate within or under the maximum operating limits.