Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
11 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
Format |
Premier Column |
Surface Area |
185 |
System |
UPLC |
Particle Technology |
CSH |
Technique |
LC |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
150 mm |
Carbon Load |
15 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
ACQUITY UPLC |
Product Type |
Columns |
Units per Package |
1 pk |
ACQUITY Premier CSH C18 Column 1.7 µm, 2.1 x 150 mm, 1/pk
Use the wide range of selectivity of the ACQUITY Premier CSH C18 Column in the broadest usage areas. Additionally, the ACQUITY Premier CSH C18 Column provides a high level of essential performance characteristics like improved peak shape for crucial substances, less column bleed, and more effectiveness.
Since the ACQUITY Premier CSH C18 Column has been created for the worldwide market, you can create procedures that are simple to replicate even if your laboratories are located all over the world. The lab equipment provides reliable, transferrable methods. You can be sure that the lab equipment will not need to be replaced frequently and will produce consistent results because only the toughest conditions are employed during the construction of the ACQUITY Premier CSH C18 Column.
Without actually employing trifluoroacetic acid (TFA), the CSH technology in the ACQUITY Premier CSH C18 Column offers TFA (Trifluoroacetic Acid) peak shape performance. As a result, it provides good outcomes while avoiding TFA's drawbacks. A more MS-friendly mobile phase, like formic acid, results in increased peak performance. In addition to this, because formic acid does not have the lingering chromatographic effects of an ion-pairing agent, the ACQUITY Premier CSH C18 Column enables faster and simpler technique development. The maximum loading of basic chemicals separated under volatile, acidic, low pH mobile-phase conditions is also provided by CSH technology. Since narrower preparative columns can be used, solvent usage and fraction quantities are decreased as a result of the improved loadability.
Store your analytes and samples in the neutral and chemically stable
What Is The pH Range For The ACQUITY Premier CSH C18 Column?
This particular ACQUITY Premier CSH C18 Column offers a wide pH range of 1-11 pH.
What Maximum Pressure Is Recommended For ACQUITY Premier CSH C18 Column?
The ACQUITY Premier CSH C18 Column listed here has a recommended maximum pressure of 18,000 psi (1240 Bar).