ACQUITY PREMIER CSH C18 Column 186009462 angle right

SKU: 186009462
ACQUITY Premier CSH C18 Column 1.7 µm, 2.1 x 150 mm, 1/pk

ACQUITY Premier CSH C18 Column | 186009462


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

ACQUITY Premier CSH C18 Columns overcome peak shape asymmetry and poor loading capacity for basic compounds when using low ionic strength mobile phase. The surface charge enables fast column equilibration when switching from low to high pH mobile phases. MaxPeak High Performance Surface hardware technology significantly reduces unwanted analyte/surface interactions that can lead to poor peak shape and losses in signal intensity.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Hybrid

  • pH Range Min

    1 pH

  • pH Range Max

    11 pH

  • Maximum Pressure

    18000 psi (1240 Bar)

  • Endcapped

    Yes

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    1.7 µm

  • Endfitting Type

    Parker-style

  • Pore Size

    130 Å

  • Format

    Premier Column

  • Surface Area

    185

  • System

    UPLC

  • Particle Technology

    CSH

  • Technique

    LC

  • USP Classification

    L1

  • Inner Diameter

    2.1 mm

  • Length

    150 mm

  • Carbon Load

    15 %

  • eCord

    Yes

  • UNSPSC

    41115709

  • Brand

    ACQUITY UPLC

  • Product Type

    Columns

  • Units per Package

    1 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

ACQUITY Premier CSH C18 Column 1.7 µm, 2.1 x 150 mm, 1/pk

Use the wide range of selectivity of the ACQUITY Premier CSH C18 Column in the broadest usage areas. Additionally, the ACQUITY Premier CSH C18 Column provides a high level of essential performance characteristics like improved peak shape for crucial substances, less column bleed, and more effectiveness.

Since the ACQUITY Premier CSH C18 Column has been created for the worldwide market, you can create procedures that are simple to replicate even if your laboratories are located all over the world. The lab equipment provides reliable, transferrable methods. You can be sure that the lab equipment will not need to be replaced frequently and will produce consistent results because only the toughest conditions are employed during the construction of the ACQUITY Premier CSH C18 Column.

Without actually employing trifluoroacetic acid (TFA), the CSH technology in the ACQUITY Premier CSH C18 Column offers TFA (Trifluoroacetic Acid) peak shape performance. As a result, it provides good outcomes while avoiding TFA's drawbacks. A more MS-friendly mobile phase, like formic acid, results in increased peak performance. In addition to this, because formic acid does not have the lingering chromatographic effects of an ion-pairing agent, the ACQUITY Premier CSH C18 Column enables faster and simpler technique development. The maximum loading of basic chemicals separated under volatile, acidic, low pH mobile-phase conditions is also provided by CSH technology. Since narrower preparative columns can be used, solvent usage and fraction quantities are decreased as a result of the improved loadability.

Store your analytes and samples in the neutral and chemically stable

What Is The pH Range For The ACQUITY Premier CSH C18 Column?

This particular ACQUITY Premier CSH C18 Column offers a wide pH range of 1-11 pH.

What Maximum Pressure Is Recommended For ACQUITY Premier CSH C18 Column?

The ACQUITY Premier CSH C18 Column listed here has a recommended maximum pressure of 18,000 psi (1240 Bar).