Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
T3 |
Silanol Activity |
Medium |
Particle Shape |
Spherical |
Particle Size |
1.8 µm |
Endfitting Type |
Parker-style |
Pore Size |
100 Å |
Format |
Premier Column |
Surface Area |
230 |
System |
UPLC |
Particle Technology |
HSS |
Technique |
LC |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
150 mm |
Carbon Load |
11 % |
eCord |
Yes |
UNSPSC |
41115709 |
Brand |
ACQUITY UPLC |
Product Type |
Columns |
Units per Package |
1 pk |
ACQUITY Premier HSS T3 Column 1.8 µm, 2.1 x 150mm, 1/pk
Don’t just conquer obstacles, change your workflow forever with the ACQUITY Premier HSS T3 Column. Much more than just a general-purpose T3 column, this product offers strong retentivity of both polar and non-polar compounds thanks to its breakthrough High-Strength Silica (HSS) particle technology. Plus, if you’re using elevated backpressures during your assays, know that this T3 column is more than equipped to handle it without affecting your data set. This silica column has also earned the MaxPeak High-Performance Surface designation, which means it’s more than ready to handle difficult analytes while preventing unwanted surface-analyte interactions.
Maximizing UPLC column efficiency isn’t just about finding the right analytes or using the correct backpressures, it’s also about using equipment that promotes that increased efficiency. That’s why we’re happy to provide a T3 column that does exactly that and so much more with the ACQUITY Premier HSS T3 Column. Waters scientists heard the concerns from their peers about suing various analytes across multiple assays without affecting column performance, which is part of why the High-Strength Silica (HSS) technology was created. At Waters, we’re always committed to finding new avenues of increasing efficiency without negatively affecting data confidence, and HSS helps us to achieve that overall goal.
Both polar and non-polar compounds are prioritized with the ACQUITY Premier HSS T3 Column. That’s partially because of its general-purpose application, but also because of its adaptability to 100% aqueous mobile phases. With that kind of flexibility, you’ll be able to perform UPLC separations and pave a successful path toward MS adoption easily. And if you’re worried about data reproducibility, it’s worth noting here that the ACQUITY Premier HSS T3 Column belongs to the MaxPeak High Performance Surface (HPS) classification, a designation reserved for columns that incorporate technology that reduces unwanted surface-analyte interactions. This all adds up to an essential chromatography consumable that you can use time and again confidently.
Want to increase speed and resolution with a different column chemistry?
The ACQUITY Column family withholds 8 UPLC particles of various substrates, 22 stationary phases, 7 application-specific UPLC column chemistries and so much more. Shop ACQUITY Columns to find the perfect fit for your assays. We have everything from Phenyl-Hexyl to peptide column chemistries ready to help you achieve great success in the lab.
Success in the lab is dictated by a variety of factors and systems that have to work well together to produce desirable results. No matter if you need lab informatics, quality control reference materials or specialized equipment for your LC-MS systems, you’ll find what you need at Waters. Shop for lab equipment now and get back to improving the science of tomorrow.
What are the ACQUITY Premier HSS T3 Column Care and Use Directions?
Refer to the ACQUITY Premier Column Care and Use Manual for those details.
What Is The Maximum Pressure Recommended For The ACQUITY Premier HSS T3 Column?
The ACQUITY Premier HSS T3 Column listed here offers a maximum pressure of 18000 psi (1240 Bar).