Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
T3 |
Silanol Activity |
Medium |
Particle Shape |
Spherical |
Particle Size |
1.8 µm |
Endfitting Type |
Parker-style |
Pore Size |
100 Å |
Format |
VanGuard FIT Cartridge |
Surface Area |
230 |
System |
UPLC |
Particle Technology |
HSS |
Technique |
LC |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
5 mm |
Carbon Load |
11 % |
UNSPSC |
41115709 |
Brand |
ACQUITY UPLC |
Product Type |
Guards |
Units per Package |
3 pk |
ACQUITY Premier HSS T3 VanGuard FIT Cartridge, 1.8 µm, 2.1 x 5 mm, 3/pk
When conducting important analysis, the last thing you need to be concerned about is your analytical column not functioning properly due to internal fouling. With the ACQUITY Premier HSS T3 VanGuard FIT Cartridge, we have created a method to stop performance decreases in the ACQUITY Premier HSS T3 Column brought on by fouling. To offer improved protection against particulate pollutants, this guard cartridge integrates smoothly into your current workflow. It is important to note that the use of this cartridge does not supplant appropriate sample purification procedures. It only aids in the removal of any particle pollutants that could still be present in the mobile phase stream. For improved protection and longer column lives, incorporate the ACQUITY Premier HSS T3 VanGuard FIT Cartridge into your workflow right now.
A reusable option for safeguarding your ACQUITY Premier HSS T3 Column is the ACQUITY Premier HSS T3 VanGuard FIT Cartridge. You can simply replace a worn-out cartridge with a new one once it has been in use. Before using, make sure to thoroughly inspect these cartridges because you do not want any residual impurities to seep into the lining of your column. A chemically and mechanically stable column protection option is provided by the ACQUITY Premier HSS T3 VanGuard FIT Cartridge, which has the same inner diameter and pH range as the ACQUITY Premier HSS T3 Column.
The most stringent cGMP and ISO 9001 regulations are followed in the production of the ACQUITY Premier HSS T3 VanGuard FIT Cartridges. Each lab equipment is carefully examined before being certified for use, assuring that it will perform at its peak and increase the selectivity, sensitivity, and speed of your study. The ACQUITY Premier HSS T3 VanGuard FIT Cartridges are appropriate for analytical applications since they are made from the same premium components as the ACQUITY UPLC columns.
You may also want to learn more about the Neutrals QC Reference Material.
What pH Range Does The ACQUITY Premier HSS T3 VanGuard FIT Cartridge Work With?
This ACQUITY Premier HSS T3 VanGuard FIT Cartridge works well with the 2-8 pH range.
What Is The Maximum Pressure That The ACQUITY Premier HSS T3 VanGuard FIT Cartridge Can Tolerate?
This particular ACQUITY Premier HSS T3 VanGuard FIT Cartridge can tolerate a maximum of 18000 psi (1240 Bar) pressure.