Suggested Use: Peptide Separations, Peptide Analysis, Peptide Mapping
Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Temperature Limits |
80 C |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
1.7 µm |
Endfitting Type |
Parker-style |
Pore Size |
130 Å |
QC Tested |
Peptide |
Format |
Premier Column |
Surface Area |
185 |
System |
UHPLC, UPLC |
Particle Technology |
BEH |
Technique |
LC |
USP Classification |
L1 |
Inner Diameter |
2.1 mm |
Length |
150 mm |
Carbon Load |
18 % |
eCord |
Yes |
UNSPSC |
41115711 |
Application |
Peptide |
Brand |
ACQUITY UPLC |
Product Type |
Columns |
Units per Package |
1 pk |
ACQUITY Premier Peptide BEH C18 Column, 130Å, 1.7 µm, 2.1 x 150 mm, 1/pk
Maximize throughput and increase reproducibility of desired results with the ACQUITY Premier Peptide BEH C18 Column. Ethylene-bridged hybrid (BEH) technology is built into every one of these UPLC columns because of the terrific peak shape it can offer scientists working under reverse-phase liquid chromatographic conditions. Even more, this product offers ultra-low column bleed, resulting in data you can actually trust and reproduce easily.
Peptide synthesis and characterization is one of the biggest obstacles put in front of scientists today. But with the ACQUITY Premier Peptide BEH C18 Column, that obstacle is never a worry. That’s because this column offers a wide pH range and outstanding temperature stability in peptide mapping, proteomics and other peptide-focused assays. Plus, with a low-positive-charged surface on the column, TFA-containing eluents can be used.
Are peptide separations by UPLC your goal?
The separation of peptides can sometimes be difficult, but it doesn’t have to be with the ACQUITY Premier Peptide BEH C18 Column. This column eliminates the need to compromise between a traditional reversed-phase eluent that delivers sharp peaks and one that reduces the MS signal, too. Scientists across the globe love this kind of versatility and reliability, especially since these factors can lead to increase business productivity and profitability.
While the UPLC application is demanding, this UPLC component is designed to provide superior resolution that’s easily reproducible. But to make sure your column lasts across many successful assays, we recommend you buy an ACQUITY Premier BEH C18 VanGuard FIT Cartridge to extend column lifetime. This helpful tool simply threads into your existing column and protects it from sample and matrix contaminants. That kind of protection is at the forefront of Waters products
This UPLC column also belongs to the MaxPeak Premier classification, which is reserved for LC products delivering premium chromatographic performance while working hard to reduce any unwanted analyte-surface interactions. This especially comes in handy during protein characterization, as reversed-phase chromatography can be demanding and cause stress on any involved products.
Need to stock your lab with the right equipment and tools?
Shop for lab equipment now to explore everything we have to offer.
What’s the Maximum Pressure Allowed by the ACQUITY Premier Peptide BEH C18 Column?
The ACQUITY Premier Peptide BEH C18 Column can withstand pressures of up to 18,000 PSI, but of course we recommend you subject this column to pressures below that threshold.