Symmetry C18 Sentry Guard Cartridge, 100Å, 5 µm, 3.9 mm X 20 mm, 2/pk

Symmetry C18 Sentry Guard Cartridges | WAT054225


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

Symmetry C18 columns feature monofunctionally bonded C18 ligands on a high purity base-deactived silica. Symmetry columns have the tightest column specifications in the industry giving resulting highly reproducible chromatographic results.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Silica

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Silanol Activity

    Low

  • Particle Shape

    Spherical

  • Particle Size

    5 µm

  • Pore Size

    100 Å

  • Format

    Sentry Guard Cartridge

  • Surface Area

    335

  • System

    HPLC

  • USP Classification

    L1

  • Inner Diameter

    3.9 mm

  • Length

    20 mm

  • Carbon Load

    19 %

  • UNSPSC

    41115709

  • Brand

    Symmetry

  • Product Type

    Guards

  • Units per Package

    2 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

Symmetry C18 Sentry Guard Cartridge, 100Å, 5 µm, 3.9 mm X 20 mm, 2/pk

Get enhanced column lifetime by using the Symmetry C18 Sentry Guard Cartridge. The guard cartridge is a type of protective lab equipment that is installed between the injector and the analytical column. It performs by removing the chemical impurities and suspended solids from reaching the analytical column.

The Symmetry C18 Sentry Guard Cartridge is manufactured using the same high-performance packing materials that are used in all of Waters analytical columns. It has been designed and developed especially for situations where increased capacity for biological fluid cleanup and/or temperature control is required.

Like all Waters equipment, the Symmetry C18 Sentry Guard Cartridge is manufactured in a cGMP, ISO 9001 certified plant using ultra-pure reagents. In addition to this, each batch of the Symmetry C18 Sentry Guard Cartridge packing material is tested chromatographically with acidic, basic, and neutral analytes. As always, the results are held to the highest standards and the narrowest specification ranges to assure excellent, reproducible performance every single time.

To get information regarding contacting our various offices and to shop for lab equipment, be sure to further explore our website. We have all available products, technology, and lab equipment available for online purchase through our online shop, and you are welcome to contact Waters at any time to ask about product specifications or other questions you may have.

You may also be interested in the Reversed-Phase QC Reference Material, with a collection of mixtures and standards which allow you to evaluate and benchmark your chromatography system before analysis of critical material. Since this Reversed-Phase QC Reference Material contains compounds that could be challenging to separate, it is a significantly complex reference material mixture and can be used with a variety of column chemistries and dimensions, and system hardware. This kit contains 7 compounds including uracil, butylparaben, naphthalene, propranolol, dipropyl phthalate, acenaphthene, and amitriptyline at pH 7.

What Precautions Need To Be Observed With The Symmetry C18 Sentry Guard Cartridge?

Only use Waters analytical columns of matching chemistry and particle size with the Symmetry C18 Sentry Guard Cartridge. It is crucial that a high-performance matching column is used to ensure that the resolution is not compromised. Please note that the Symmetry C18 Sentry Guard Cartridge may need to be replaced periodically as determined by the sample contamination. Some indications that the cartridge needs to be replaced include increasing backpressure above a set limit and sudden appearance of split peaks.