Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Silica |
pH Range Min |
2 pH |
pH Range Max |
8 pH |
Temperature Limits |
45 C |
Maximum Pressure |
1500 psi (100 Bar) |
Endcapped |
Yes |
Silanol Activity |
High |
Particle Shape |
Irregular |
Particle Size |
10 µm |
Pore Size |
125 Å |
Format |
Radial-Pak Column |
Surface Area |
330 |
System |
HPLC Preparative |
Technique |
LC, LC/MS |
USP Classification |
L1 |
Inner Diameter |
8 mm |
Length |
100 mm |
Carbon Load |
10 % |
UNSPSC |
41115709 |
Brand |
µBondapak |
Product Type |
Columns |
Units per Package |
1 pk |
µBondapak C18 Radial-Pak Column, 125Å, 10 µm, 8 mm X 100 mm, 1/pk
Even though several rivals claim to have µBondapak-like selectivity in their columns, Waters' µBondapak packing material is the only real µBondapak packing in the field. Waters µBondapak packing columns have set a high bar for reproducible, high-performance chromatographic columns that are difficult to replicate, making them the world's most often referred and sought columns.
µBondapak C18 columns are general-purpose, reversed-phase C18 columns based on 10 µm particle technology. No other column can provide the balance of resolution, throughput, and cost as a starting point for preparative chromatography.
The Waters Bondapak C18 Column is a reversed-phase, Silica-based C18 column with a pH range of 2 to 8 and a maximum pressure setting of 6000 psi (or 415 Bar). The Waters Bondapak C18 Column can be relied on to reliably produce outstanding quality and the desired results for liquid chromatography. These columns, like other Waters equipment, are built in specialized Waters facilities. All Water plants and facilities follow the most severe cGMP and ISO 9001 requirements. Each stage of the manufacturing process is rigorously checked and managed, providing the best quality equipment in your labs.
Visit our website or browse our collection to find products that will work with your setup or to shop for lab equipment to replace your current inventory and expand your existing equipment portfolio as needed. You will also be able to utilize our website to contact a member of our global client support staff if you have any questions or problems, or if you need assistance with product information and the right equipment selection.
You might also be interested in the Reversed-Phase QC Reference Material, which is part of the Quality Control Reference Materials portfolio. These tools enable the user to analyze and benchmark their chromatography equipment prior to performing essential material analysis. At pH 7, the Reversed-Phase QC Reference Material contains uracil, butyl paraben, naphthalene, propranolol, dipropyl-phthalate, acenaphthene, and amitriptyline. This standard mixture should be used to validate the analytical HPLC or UPLC system's benchmark performance. This QC Reference Material is a precisely prepared blend of void markers, neutral, acidic, and basic substances.
What Is The Structure Of A Phenyl Group?
A phenyl group consists of a collection of six carbon atoms arranged in a hexagonal planar ring. Five of these carbon atoms are individually connected to hydrogen atoms, while the remaining carbon is bonded to a substituent. Phenyl groups find extensive applications in the field of organic chemistry.