µBondapak C18 Guard-Pak Insert, 125Å, 10 µm, 10/pk

µBondapak C18 Guard Pak Insert | WAT088070


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

µBondapak C18 columns are general purpose, silica-based, reversed-phase C18 columns that are based on 10 µm particle technology. As a starting point for preparative chromatography, no other column can provide the balance between resolution, throughput and cost.

Specifications

  • Chemistry

    C18

  • Separation Mode

    Reversed Phase

  • Particle Substrate

    Silica

  • pH Range Min

    2 pH

  • pH Range Max

    8 pH

  • Maximum Pressure

    6000 psi (415 Bar)

  • Endcapped

    Yes

  • Silanol Activity

    High

  • Particle Shape

    Irregular

  • Particle Size

    10 µm

  • Pore Size

    125 Å

  • Format

    Guard-Pak Insert

  • Surface Area

    330

  • System

    HPLC

  • USP Classification

    L1

  • Carbon Load

    10 %

  • UNSPSC

    41115709

  • Brand

    µBondapak

  • Product Type

    Guards

  • Units per Package

    10 pk

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

µBondapak C18 Guard-Pak Insert, 125Å, 10 µm, 10/pk

Methods that call for irregular particle technology call for columns that contain µBondapak technology and C18 packing materials, a combination only offered in Waters columns. No other column has passed the stringent quality control batch tests, which is why µBondapak is one of the world’s most referenced columns and the lab equipment is known for its excellent reproducibility. Because of the unique benefits offered, it is critical to protect your µBondapak column from both particulate and chemical contamination with a µBondapak C18 Guard-Pak Insert.

This technology was developed as scientists saw reduced mechanical stability and lowered efficiency in HPLC packing materials comprised of irregular or non-spherical particles when compared with their spherical counterparts. Knowing that many methods require the use of sorbents with irregularly shaped particles, Waters committed over four decades to developing and improving reliable and consistent column performance. By manufacturing sorbents and bonded materials, Waters has been able to continue supporting columns and accessories for scientists working with irregular particles around the world. One way this ability is protected is through the use of accessories like the µBondapak C18 Guard-Pak Insert.

All Waters materials and Guard-Pak Inserts are manufactured under tightly controlled quality assurance processes and tested against narrow specification ranges, ensuring high quality and reproducible results across applications. Further testing can be performed using Reversed-Phase QC Reference Material.

This µBondapak C18 Guard-Pak Insert contains C18 sorbent and a particle size of 10 µm, with a pore size of 125 Å. 10 inserts are included in each package. Recommended pH range is 2 to 8 with a maximum pressure of 6000 psi or 415 bar.

What Happens If My µBondapak C18 Guard-Pak Insert Is Broken?

Guard-Pak Inserts fall under Waters Corporation’s warranty and service provisions. Waters will replace, at no cost, any holder or insert that fails to perform to your laboratory’s satisfaction if notice is received within 90 days of receipt of the product. Waters reserves the right to deny this return if any of the following conditions are met: damage to the insert due to abuse or misuse, damage due to use with incompatible solvents or use at incorrect temperature or pressure, failure or decreased performance due to normal use.