UNSPSC |
41115712 |
Brand |
Oasis |
Product Type |
Solid Phase Extraction |
Units per Package |
1 pk |
Chemistry |
WAX |
Endcapped |
No |
Format |
96-well Plate |
Ion Exchange Capacity |
0.6 meq/gram |
Mass Spec Compatibility |
Yes |
Mode |
Mixed mode |
Particle Size |
30 µm |
Pore Size |
80 Å |
Sorbent Substrate |
Copolymer |
Sorbent Weight |
10 mg |
Water Wettable |
Yes |
pH Range Min |
0 pH |
pH Range Max |
14 pH |
Material |
Polypropylene |
Number of Wells |
96 |
Oasis WAX 96-well Plate, 10 mg Sorbent per Well, 30 µm, 1/pk
The sorbent in the Oasis WAX 96-well plate is a polymeric reversed-phase, weak anion exchange mixed-mode sorbent that has been optimized for fast, simple, and highly selective sample preparation of strong acidic compounds. Because of the Oasis WAX sorbent's unique balance of hydrophobicity and water-wettability, you will never have to worry about poor results if individual wells of the 96-well plate dry out during the critical steps prior to sample loading. The Oasis WAX 96-well plate is intended for use on a wide range of manifold configurations and robotic liquid handling systems.
The Oasis WAX sorbent has been designed for quick, easy, and highly selective sample preparation of strong acidic compounds. The Oasis WAX Sorbent is based on Waters Oasis technology, which means it is water-wettable and will provide you with consistent results without evaporation or reconstitution. This will help you save time by eliminating the need for the time-consuming step of eluate concentration by evaporation, as well as evaporation or reconstitution if a suitable LC/MS mobile phase eluting solvent is used. It will also ensure that you can easily continue with test results without fear of poor results even if individual wells of the 96-well plate dry out.
You can shop for lab equipment on our website to meet your lab needs. We also suggest that you look into QuanRecovery with MaxPeak, 700 µL Plates, 25/pk. The QuanRecovery Plates with MaxPeak HPS, designed by LC-MS bioanalysts for LC-MS bioanalysts, reduce peptide and protein losses due to ionic interactions and nonspecific binding. Reduced losses result in improved recovery, sensitivity, and repeatability of analytical results. These 700L 96 well plates are LC-MS autosampler ready, with low residual volumes to maximize sample volume utilization. MaxPeak High Performance Surfaces are new and innovative technologies that are designed to improve analyte recovery, sensitivity, and reproducibility by reducing analyte/surface interactions that can result in sample losses.
How Do I Change a VanGuard Cartridge?
VanGuard Cartridge Columns are made of two parts: a reusable holder and a replaceable cartridge. For replacement, the following steps should be taken: Remove the LC inlet tubing from the column assembly first. A 7/16-inch and 3/8-inch wrench will be useful in removing the cartridge from the holder. It is not necessary to remove the holder from the analytical column. Remove the old guard column and replace it with the new one. Then, using the same wrenches, tighten the cartridge by applying them to the flats on the cartridge holder. After that, reconnect the LC inlet tubing and use mobile phase flow to ensure a leak-free collection.