Sep-Pak AC-2 Plus short cartridge

SKU: JJAN20229
Sep-Pak AC2 Plus Short Cartridge, 400 mg Sorbent per Cartridge, 85 µm, 50/pk

Sep-Pak® AC2 Plus Short Cartridges | JJAN20229


Streamline Purchasing with Customized Quotes

Streamline Purchasing with Customized Quotes

Shop on Waters.com and add items to your cart

Navigate to the Shopping Cart

Select Request a Quote to get your quote instantly


Product Description

Sep-Pak AC2 Plus Short cartridges contain low ash content activated carbon for applications such as the concentration of pesticides and herbicides in water or food samples. Sep-Pak AC2 is used in Japan Pesticide Method #17. These short body cartridges can attach easily to pumps and syringes for reliable, positive-pressure flow to speed up the sample processing time. They can also be fitted with removable reservoirs and used on vacuum-assisted flow devices and certain automated systems.

Specifications

  • UNSPSC

    41115712

  • Brand

    Sep-Pak

  • Product Type

    Solid Phase Extraction

  • Units per Package

    50 pk

  • Chemistry

    AC2

  • Format

    Plus Short Cartridge

  • Mass Spec Compatibility

    Yes

  • Mode

    Reversed Phase

  • Particle Size

    85 µm

  • Sorbent Substrate

    Activated Carbon

  • Sorbent Weight

    400 mg

  • Water Wettable

    No

  • pH Range Min

    1 pH

  • pH Range Max

    12 pH

Product Support

Documents

Documents



What do you want to do?

What do you want to do?

Related Products

Back To Top Back To Top

Sep-Pak AC2 Plus Short Cartridge, 400 mg Sorbent per Cartridge, 85 µm, 50/pk

Remove or enrich very polar organic molecules from water using the Sep-Pak AC2 Plus Short Cartridge. Being the perfect lab equipment, the Sep-Pak AC2 Plus Short Cartridges are highly hydrophobic, contain low ash content, and activated carbon. They are best suited for the analysis of analytes with particle size 85 µm. The Sep-Pak AC2 Plus Short Cartridges can be used in a variety of applications including pesticides, herbicides, especially highly polar small molecules.

Reduce solvent waste and improve workflows with the Sep-Pak AC2 Plus Short Cartridges. This is achieved by reducing background interference and eliminating unnecessary solvent pre-washing steps that are often needed for trace residue methods. The Sep-Pak AC2 Plus Short Cartridges also allow easy integration into your sample preparation protocol.

The Sep-Pak AC2 Plus Short Cartridges are manufactured in world-class facilities that ensure the highest quality standards in the industry including the cGMP (current Good Manufacturing Practices), ISO 9001, and ISO 13485. Each Sep-Pak AC2 Plus Short Cartridge is thoroughly QC tested to ensure you receive the best lab equipment and reliable results.

You may also be interested in other lab equipment such as the LCGC Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk, a product designed to provide a neutral vessel for your analytes, and HPLC tested for cleanliness to ensure your extracts and analytes remain contamination-free and you obtain reliable results. You can also shop for lab equipment and explore other Waters Sep-Pak Cartridges and more pieces in our extensive collection of chromatographic tools and equipment.

FAQs About Sep-Pak AC2 Plus Short Cartridge, 400 mg Sorbent per Cartridge, 85 µm, 50/pk

1. What is the recommended protocol for conditioning and equilibrating this cartridge?
To properly condition and equilibrate the Sep-Pak AC2 Plus Short Cartridge, begin by flushing it with 5-10 mL of a strong organic solvent, such as methanol, to activate the sorbent and remove any impurities. Follow this step by washing the cartridge with an equal volume of distilled or deionized water to equilibrate the sorbent for sample loading.
Always ensure that the conditioning solvents match the polarity of the sample to optimize retention. Proper conditioning and equilibration are essential to achieve high analyte recovery and consistent separations.

2. What types of solvents are compatible with the Sep-Pak AC2 Cartridge?
The Sep-Pak AC2 Plus Short Cartridge is compatible with a wide range of organic and aqueous solvents, making it versatile for various sample preparation protocols. Commonly used solvents include methanol, acetonitrile, water, and combinations of these. Acidic or basic modifiers, such as formic acid or ammonium hydroxide, can also be used depending on the target analyte and the application. It is important to avoid solvents or additives that are incompatible with the cartridge materials to ensure optimal performance and longevity.

3. What is the sample volume capacity of the Sep-Pak AC2 Plus Short Cartridge?
The Sep-Pak AC2 Plus Short Cartridge, with 400 mg of sorbent, has a sample volume capacity of approximately 5-10 mL, depending on the matrix and application. For optimal results, avoid overloading the cartridge by staying within the recommended volume limits. Overloading can reduce the retention capacity and compromise analyte recovery.
The cartridge's design ensures efficient extraction and separation for moderate-volume samples, making it a reliable choice for analytical workflows requiring clean, reproducible results.

What Does Solid-Phase Extraction Enable Scientists To Do?

Solid-Phase Extraction (SPE) is a sample preparation technology that combines chromatographic packing material contained in a device and solid particles, to chemically separate the different components of a sample. It reduces chromatographic complexity and makes things more efficient. This is achieved by minimizing risks associated with matrix effects. It increases the signal to noise and improves detection limits. Variability in analytical results is reduced and there is an increased robustness of analysis with the use of Solid-Phase Extraction (SPE). With the use of Solid-Phase Extraction (SPE), system downtime is reduced and the lifetime of the analytical columns is increased as well.