Separation Mode |
Reversed Phase |
Detection Method |
UV |
Formulation |
Liquid |
Storage Condition |
Room Temperature |
System Type |
LC |
Quantitative |
Yes |
Shelf Life |
12 Months |
Shipping Condition |
Ambient |
Volume |
2 mL |
Type |
Reference |
UNSPSC |
41116107 |
Application |
Small Molecule |
Product Type |
QC |
Units per Package |
1 pk |
Reversed-Phase QC Reference Material
Use the products in the Reversed-Phase QC Reference Material to evaluate and benchmark your chromatography system before analysis of critical material. The portfolio of Quality Control Reference Materials is a one-of-a-kind set of standards and mixtures. The goods in the range have all been uniquely designed using Waters scientists' expertise. Because it comprises components that can be difficult to separate, the Reversed-Phase QC Reference Material is a very complicated reference material mixture. It is intended to deliver this level of complexity and is appropriate for use when performing sophisticated experiments on a regular basis. It works with a wide range of column chemistries and sizes, as well as system lab equipment.
The Reversed-Phase QC Reference Material contains 7 compounds, including uracil, butyl paraben, naphthalene, propranolol, dipropylphthalate, acenaphthene, and amitriptyline at pH 7. This standard mix should be used to confirm your analytical HPLC or UPLC system's benchmark performance. This QC Reference Material is a carefully prepared mixture that contains a void marker, as well as neutral, acidic, and basic substances.
The compounds in the lab equipment were vigorously tested, evaluated, and chosen because they provide multiple advantages. These include excellent benchmark, good peak shape on UV, and acceptable use with a variety of columns.
We recommend that you also invest in the LCMS Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk. All Waters LCMS Certified vials are manufactured using stringent quality control and handling methods. Mass spectrometers are used to evaluate them, and they come with a certificate of analysis that includes the reference and vial scan for the production lot. The Waters LCMS Certified Clear Glass 12 x 32 mm Screw Neck Vial's screw-top mechanically retains the septum in place during piercing and also produces a good seal. The preslit PTFE/Silicone septa is ideal for numerous injections and sample storage because of its excellent resealing capabilities. It can operate at temperatures ranging from -40°C to 200°C.
What Is The Shelf Life Of The Reversed-Phase QC Reference Material?
The Reversed-Phase QC Reference Material listed here has a shelf life of 12 months.
How Should The Reversed-Phase QC Reference Material Be Stored?
This particular Reversed-Phase QC Reference Material should be stored at Room Temperature.