Separation Mode |
Reversed Phase |
Detection Method |
MS |
Formulation |
Liquid |
Storage Condition |
Room Temperature |
System Type |
MS |
Shelf Life |
12 Months |
Shipping Condition |
Ambient |
Volume |
10 mL |
Type |
Mobile Phase |
UNSPSC |
41116105 |
Application |
Pesticides |
Product Type |
Standards |
Units per Package |
2 pk |
Ammonium Acetate 1M pH 5
Around the world, about 500 chemicals are frequently employed for crop protection. Rapid multi-residue screening and quantification procedures are needed to efficiently discover residue infractions and protect consumers as global trade grows. The management of a large number of MRM transitions is required for effective multi-residue approaches.
Using a single LC-MS/MS Method for screening, identification, and quantification of over 400 pesticides in a complex matrix without compromising Data Quality is one of the main goals of such tests.
The HPLC Standard Ammonium Acetate 1M pH 5 is used with the pesticide screening application. The Ammonium Acetate 1M pH 5 equipment listed here includes two 10 mL ampules of 1M pH 5.0 Ammonium Acetate. As part of the overall experiment setup, the ACQUITY UPLC H-Class system, ACQUITY BEH C18 Column, and Waters LC Multi-residue Pesticide Standards Kit are used to create Mobile Phases using water and methanol.
The Reverse-Phase Ammonium Acetate 1M pH 5 Standard for Pesticide Testing is packaged in two units, each with a liquid volume of 10 mL. The Ammonium Acetate 1M pH 5 should be stored at room temperature and pressure, and it has a shelf life of 12 months.
To find other Standards and lab equipment manufactured by Waters, please browse through our brochure or check out our website. Both mediums will provide you with a comprehensive apparatus list, and you can shop for lab equipment as per your needs. You may also be interested in reviewing Reversed-Phase QC Reference Material; The inventory of Quality Control Reference Materials is a one-of-a-kind collection of standards and mixtures. Before analyzing essential material, the user can assess and benchmark their chromatography system with these goods. The goods in the portfolio have all been specially designed by Waters scientists. The Reversed-Phase QC Reference Material is a particularly difficult-to-separate reference material mixture. It is intended to give this level of complexity and is appropriate for use when performing sophisticated experiments on a regular basis. It works with a wide range of column chemistries and sizes, as well as system hardware. At pH 7, the Reversed-Phase QC Reference Material contains uracil, butylparaben, naphthalene, propranolol, di-propylphthalate, acenaphthene, and amitriptyline, among other chemicals. This standard mix should be used to confirm your analytical HPLC or UPLC system's benchmark performance. This QC Reference Material is a carefully prepared mixture that contains a void marker, as well as neutral, acidic, and basic substances.
When It Pertains To Chromatography, What Does The Term Resolution Refer To?
Resolution may be utilized to optimize separations because it is a function of peak width and retention time, both of which are fundamental aspects of the chromatographic process.