Designed alongside the BioResolve SCX columns, the IonHance CX-MS pH 10X Concentrate B, in MS Certified LDPE Container, was carefully optimized for use in creating a gradient for LC/MS analysis of mAb charge variant separations.
Separation Mode |
Ion Exchange Chromatography |
Detection Method |
LCMS |
Formulation |
Liquid |
Storage Condition |
Room Temperature |
System Type |
LC/MS |
Shelf Life |
12 Months |
Shelf life upon reconstitution |
1 Week |
Volume |
100 mL |
Type |
Mobile Phase |
UNSPSC |
41116107 |
Application |
Protein |
Brand |
IonHance |
Product Type |
Standards |
Units per Package |
1 pk |
IonHance CX-MS pH Concentrate B pH 8.5 in MS Certified LDPE Container (10X Concentrate)
Cation-exchange chromatography linked to mass spectrometry (CX-MS) analysis of native proteins is a reliable method of identifying micro heterogeneities in biopharmaceuticals, notably monoclonal antibodies (mAbs). Charge-variant analysis can be used with CX-MS to fingerprint chemical and enzymatic alterations that occur throughout the manufacture, purification, formulation, and storage of mAbs. These changes have the potential to impact the structure and biological action of medicines; thus they must be identified.
Due to the use of nonvolatile salts and high ionic strength, ion-exchange chromatography (IEX) was formerly incompatible with mass spectrometry. The introduction and improvement of volatile, salt-mediated pH gradients, on the other hand, allows CX-MS to be used. Waters has built a solid CX-MS platform that includes BioResolveTM SCX mAb 3 μm Columns, trace metal certified labware, and tailored buffers. These lab equipment are useful for both intact and subunit mAb studies.
High mass spectrum quality is ensured by WatersTM IonHanceTM CX-MS pH Concentrate B. The lab equipment comes in one-liter trace metal certified low-density polyethylene bottles with 100 mL aliquots of 10x strength combinations (proven trace ppb values of sodium, potassium, and calcium).
Concentrate B is designed to produce a 160 mM ammonium acetate mobile phase with a pH of 8.5. In addition to this, these concentrates are made with 20% acetonitrile to prevent bacterial development.
We recommend that you also explore and invest in the BioResolve SCX mAb Column with VanGuard FIT, 3 µm, 2.1 mm X 50 mm, 1/pk. BioResolve SCX mAb columns are 3 μm corrosion-resistant columns that comprise non-porous polymer-based particles grafted with a multi-component network of negatively charged sulfonic acid ligands that has been thoroughly tuned. Using robust salt or pH gradient approaches, this unique column technology enables consistent, high-resolution, charged-based separations of mAbs and other proteins in both LC and LC-MS applications. This package also incorporates VanGuardTM Fully Integrated Technology (FIT), which extends the life of the column without compromising biomolecule component resolution.
What Is The Shelf Life Of The IonHance CX-MS pH Concentrate B pH 8.5 in MS Certified LDPE Container (10X Concentrate)?
The IonHance CX-MS pH Concentrate B pH 8.5 in MS Certified LDPE Container (10X Concentrate) listed here has a shelf life of 12 Months.
What Is The Shelf Life Of The IonHance CX-MS pH Concentrate B pH 8.5 in MS Certified LDPE Container (10X Concentrate) Upon Reconstitution?
Upon Reconstitution, the product’s shelf life is 1 Week.