ACQUITY RDa Waters_connet LockMass kit contains the LockMass Concentrate (LeuEnk, Caffeine, Pentenasulfonic Acid) and the Dilluent. The LockMass solution is to compensate for mass shifts at changing lab temperature for BioAccord.
Separation Mode |
Reversed Phase |
Detection Method |
LCMS |
Formulation |
Liquid |
Storage Condition |
Room Temperature |
System Type |
LC/MS |
Instrument |
ACQUITY |
Shelf Life |
12 Months |
Shipping Condition |
Ambient |
UNSPSC |
41116107 |
Application |
Lock Mass |
Brand |
ACQUITY |
Product Type |
Standards |
ACQUITY RDa Waters_connect LockMass Kit
Achieve accurate mass measurements and increased confidence in your data with the ACQUITY RDa Waters_connect LockMass Kit. Specifically designed to compensate for mass shifts at changing lab temperatures for BioAccord, this kit contains a LockMass Concentrate (LeuEnk, Caffeine, Pentenasulfonic Acid) and a Diluent. By calibrating the mass spectrometer, it ensures precise measurements regardless of temperature variations in your lab equipment. The ACQUITY RDa Waters_connect LockMass Kit is user-friendly, requiring a simple process.
Just add the LockMass Concentrate to the Diluent, mix by vortexing, and the solution is ready to use. Furthermore, the kit offers stability for 12 months when stored at room temperature, ensuring long-lasting performance.
This kit proves to be an invaluable tool for laboratories utilizing the ACQUITY RDa Detector in conjunction with the BioAccord system. By guaranteeing accurate mass measurements, it enables the generation of reliable and reproducible results. If you need vials to hold the solutions, try the TruView pH Control LCMS Certified Clear Glass, 12 x 32 mm, Screw Neck Vial, with Cap and preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk.
Enjoy the following features of the ACQUITY RDa Waters_connect LockMass Kit: its specially formulated mixture that compensates for mass shifts caused by changing lab temperatures, its ease of use, and its stability for 12 months at room temperature.
By using this kit, you can benefit from accurate mass measurements, achieve reproducible results, and gain increased confidence in your data. Ensure the integrity of your mass spectrometry analyses and order your ACQUITY RDa Waters_connect LockMass Kit today.
In addition to the above, the LockMass Concentrate consists of LeuEnk, Caffeine, and Pentenasulfonic Acid, each with distinct mass-to-charge ratios, allowing for effective mass spectrometer calibration. The Diluent, a solution of water and methanol, serves to dilute the LockMass Concentrate to the desired concentration. The kit is available in a pack of one, providing a convenient and efficient solution for your mass calibration needs.
How do I use the ACQUITY RDa Waters_connect LockMass Kit?
To use the kit, simply add the LockMass Concentrate to the Diluent and vortex to mix. The solution is then ready to use. The kit is also stable for 12 months when stored at room temperature.
What is the shelf life of the ACQUITY RDa Waters_connect LockMass Kit?
The kit is stable for 12 months when stored at room temperature.