Separation Mode |
Reversed Phase |
Detection Method |
UV |
Formulation |
Liquid |
Storage Condition |
Room Temperature |
System Type |
LC |
Shelf Life |
24 Months |
Shipping Condition |
Ambient |
Volume |
10 mL |
Type |
Reference |
UNSPSC |
41116107 |
Application |
System Calibration, System Performance |
Brand |
ACQUITY UPLC |
Product Type |
Standards |
Units per Package |
1 pk |
ACQUITY UPLC / UV Start-up Standards Kit
Acquity UPLC standards, 2 Ampules (10ml each of standard solutions containing):
The ACQUITY UPLC / UV Start-up Standards Kit contains standards appropriate for verification of system reproducibility, flow rate, gradient performance, detector linearity, detector accuracy, injector accuracy, injector carryover. The ACQUITY UPLC / UV Start-up Standards Kit is used for system calibration, as well as verifying system performance when needed. This reversed phased standard should be stored at room temperature and pressure and has a shelf life of 24 months. The ACQUITY UPLC / UV Start-up Standards Kit ships 1 per package and contains 10 mL of standard volume in each of the solutions.
It is highly advisable to use protective lab gear when handling the ACQUITY UPLC / UV Start-up Standards Kit, as it may cause irritation via all routes of entry into the body, including inhalation, skin, eye, and ingestion. The chemicals in the ACQUITY UPLC / UV Start-up Standards Kit should be considered hazardous, and any direct physical contact with them is highly recommended to be avoided. If the chemicals come in contact with skin or eyes directly, please flush the affected area with plenty of water and contact a physician.
You can review our catalog, or browse through our website to shop for lab equipment as per your laboratory requirements. On our website, you will also be able to review the extensive Waters collection of offerings and products, including additional lab equipment that can be used alongside the ACQUITY UPLC / UV Start-up Standards Kit.
We also recommend checking out the Reversed-Phase QC Reference Material; the Reversed-Phase QC Reference Material contains 7 compounds, including uracil, butyl paraben, naphthalene, propranolol, dipropyl-phthalate, acenaphthene, and amitriptyline at pH 7. This standard mix should be used to confirm the benchmark performance of your analytical HPLC or UPLC system. This particular QC Reference Material is a specially formulated mix that includes a void marker, neutral, acidic, and basic compounds.
How Does Obtaining A High Resolution In Chromatography Results Assist The Analysis?
In the field of chromatography, resolution serves as a function of peak width and retention time, both of which are inherent properties of the chromatographic process. Resolution measurement can be and frequently is used for optimizing separations. The higher the resolution obtained, the better results can be analyzed and with higher accuracy.