Separation Mode |
GPC/GFC/SEC |
Detection Method |
RI/ELSD, UV |
Formulation |
Solid |
Storage Condition |
4C (Fridge) |
System Type |
LC |
Shelf Life |
36 Months |
Shelf life upon reconstitution |
1 Week |
Shipping Condition |
Ambient |
Tolarence |
10% (Mp) |
Mass |
0.25 g |
Type |
Calibration |
UNSPSC |
41116107 |
Application |
Gel Filtration |
Product Type |
Standard Kits |
Units per Package |
10 pk |
Polyacrylic Acid Standards Kit
Are you trying to use Gel Permeation Chromatography (GPC) to analyze a chosen sample?
Before doing so, we recommend benchmarking your LC system for performance with the proper standards. For GPC techniques, we recommend purchasing the Polyacrylic Acid Standards Kit. This kit comes with 10 GPC standards specially formulated to help you verify system performance before proceeding with GPC analysis. What’s more, this kit offers a shelf life of 36 months, so you can get the most out of this standard over time. It’s important to note that the shelf life upon reconstitution is only one week. Add the Polyacrylic Acid Standards Kit to your lab’s toolkit to be ready for GPC performance verification, or ask your lab manager to include this standards kit with your lab’s next order from Waters. Either way, if you find yourself in need of quality control reference materials, you’ll find everything you need at Waters Corporation.
Why are internal standards so important?
For one, they can accurately show you whether your LC system is performing as it should or if calibrations need to be made. That’s because an internal standard should elute exactly as designed, then you can make the proper calibrations if the signal is out of alignment. But in the case of Gel Permeation Chromatography, you need specific standards to use on your LC system to verify performance. That’s why we recommend the Polyacrylic Acid Standards Kit whenever you need to get ready to perform separations and analysis using GPC techniques.
If you just need a normal calibration standard for your GPC system, we have that as well with the GPC Calibration 190K Standard. This standard can help you perform essential system calibrations before performing any separations.
No matter what you need for success in the lab, you’ll find it at Waters. We have a full line of products and resources to suit your goals, including full LC-MS systems, lab informatics, quality control reference materials and so much more. Simply shop lab equipment
What Molecular Weight Range Does the Polyacrylic Standards Kit Cover?
The Polyacrylic Standards Kit covers a molecular weight range from 1,000 Daltons to 1,000,000 Daltons.