Separation Mode |
GPC/GFC/SEC |
Detection Method |
RI/ELSD, UV |
Formulation |
Solid |
Storage Condition |
4C (Fridge) |
System Type |
LC |
Shelf Life |
36 Months |
Shelf life upon reconstitution |
1 Week |
Shipping Condition |
Ambient |
Type |
Calibration |
UNSPSC |
41116107 |
Product Type |
Standard Kits |
Units per Package |
10 pk |
Polystyrene ReadyCal Standards 2 mL Kit
To suit your chromatographic requirements, Waters offers a selection of well-characterized polymer standards, including kits and individual standards. Both aqueous and non-aqueous applications have standards available.
Without needing to weigh chemicals, the Polystyrene ReadyCal Standards 2 mL Kit allows you to rapidly and accurately generate a multi-point calibration curve. Each vial includes a polymer mixture spanning a molecular weight range, allowing each component's baseline resolution to be determined. The kits are made to pour solvent directly into the vial and mix it. Simply fill the vial with solvent, set it aside for 2 hours, gently shake, and feed it into your autosampler for analysis.
Polystyrene ReadyCal Standards 2 mL Kit contains thirty autosampler vials which contain 4 polystyrene standards per vial. There are three separate molecular weight ranges in each kit, 10 units of each of the three molecular weight standards. Just add solvent to the vial, let it stand for 2 hours, shake gently and load into your autosampler for analysis. Each kit comes with detailed instructions for proper usage. Mw Part [Da]* / PDI 560* / < 1.50 : 1200 / < 1.50 : 3200 / < 1.15 : 8000 / < 1.15 : 18000 / < 1.15 : 33000 / < 1.15 : 62000 / < 1.15 : 120000 / < 1.15 : 280000 / < 1.15 : 560000 / < 1.15 : 1200000 / < 1.50 : 2500000 / < 1.50.
With the right lab equipment, you can boost your productivity. You can browse our website and refer to our catalog to shop for lab equipment to replenish your stock and add to your existing equipment portfolio. Additionally, there are comprehensive literature guides to shed light on our technology and the research conducted to produce these world-class lab equipment. You can address your questions and concerns to a member of our team in one of our many offices across the world.
You might also like the Waters BPA Method Kit; it's a Waters ACQUITY UPLC solution for the analysis of Bisphenol A in Drinking Water that is fully compliant with ASTM Method D7574-09. Optimized for use with the ACQUITY system, this kit contains the following: ACQUITY BEH C18, 1.7um, 2.1 x 50mm Column; ACQUITY Isolator Column; Oasis HLB 5cc (200mg) LP Glass Cartridges and LCMS Certified Vials. Included in ASTM Method D7574-09, these products have been selected to ensure the highest performance available.
How Should The Polystyrene ReadyCal Standards 2 mL Kit Be Stored?
The Polystyrene ReadyCal Standards 2 mL Kit listed here should be stored refrigerated at 4 degrees C.