ACQUITY UPLC Columns

ACQUITY UPLC Columns

Increase speed, sensitivity, and resolution, without compromising data integrity

Increase speed, sensitivity, and resolution, without compromising data integrity

Increasing sample throughput, achieving unmatched resolution, and improving analyte sensitivity are priorities for your separation goals. With Waters ACQUITY UPLC Columns, you can meet all your method requirements and substantially reduce your analysis time and cost-per-sample. 

Waters ACQUITY UPLC Columns’ sub-2-μm particle chemistries enable chromatographers to harness the separation efficiency improvements at increased flow rates of ultra-performance liquid chromatography (UPLC) technology, thereby improving analyte resolution and sensitivity as well as business productivity and profitability.  

ACQUITY UPLC Columns (IVD) harness the potential of sub-2-µm particles for faster separations with higher resolution and sensitivities. ACQUITY UPLC Columns

Mitigate unwanted interactions between analytes and metal ions associated with stainless-steel column hardware with ACQUITY Premier Columns. 

Specifications

Overview

  • Best-in-class column efficiency for superior separation speed, sensitivity, and resolution
  • 8 UPLC particles of various substrate technologies, including Ethylene Bridged Hybrid (BEH), High Strength Silica (HSS), and Charged Surface Hybrid (CSH)
  • 22 stationary phases, including C18, Phenyl-Hexyl, C8, Embedded-Polar, C4, HILIC, Amide, Diol, Cyano, and PFP
  • 7 application-specific UPLC Column chemistries for SEC, proteins, peptides, oligonucleotides, glycan, and amino acid analysis
  • More than 50 different column dimensions and configurations, with internal column diameters ranging from 1.0–4.6 mm and column lengths ranging from 30–300 mm
  • Prolonged column lifetimes with optional VanGuard Cartridges specifically designed using ACQUITY stationary phases

Recommended Use: For improved speed, sensitivity, and resolution in methods development.


ACQUITY UPLC BEH Column Characteristics

ACQUITY UPLC BEH Column Characteristics

ACQUITY UPLC BEH C18 Columns
  • Universal C18 column
  • Suitable for a diverse range of analytes
  • High efficiency
  • Industry-leading mobile phase pH 1-12 and temperature compatibility
ACQUITY UPLC BEH C8 Columns
  • Lower hydrophobicity and retention than a C18 column
  • Suitable for a diverse range of analytes
  • High efficiency
  • Industry-leading mobile phase pH 1-12 and temperature compatibility
ACQUITY UPLC BEH Shield RP18 Columns
  • Contains an embedded polar group combined with the hydrophobicity of C18
  • Complementary selectivity to a C18 column
  • Enhanced peak shape for basic compounds
  • Compatible with 100% aqueous mobile phases
  • High efficiency
ACQUITY UPLC BEH Phenyl Columns
  • Industry leading chemical stability
  • Suitable for a diverse range of analytes
  • High efficiency
  • Complimentary selectivity to straight-chain alkyl phases
ACQUITY UPLC BEH HILIC Columns
  • Improves the retention of very polar basic analytes
  • Complementary selectivity to reversed-phase
  • High efficiency
  • Exceptional chemical stability and peak shape compared to silica-based HILIC stationary phases
ACQUITY UPLC BEH Amide Columns
  • Designed to retain highly polar analytes that are too polar to retain by reversed-phase
  • Exceptional chemical stability at high pH and high temperature
  • Ideal for sugar/carbohydrate analysis
  • Exceptional retention of polar analytes spanning a wide range of polarity

ACQUITY UPLC CSH Column Characteristics

ACQUITY UPLC CSH Column Characteristics

ACQUITY UPLC CSH C18 Columns
  • Universal column choice for UV and MS applications
  • Suitable for a broad range of compounds
  • Alternate selectivity to BEH C18
  • Exceptional peak shape and increased load capacity
  • Suited for basic compounds at low pH
ACQUITY UPLC CSH Fluoro-Phenyl Columns
  • Exceptional selectivity for positional isomers, halogenated compounds and polar compounds
  • Enhanced retention of acidic compounds compared to traditional PFP-bonded stationary phases
ACQUITY UPLC CSH Phenyl-Hexyl Columns
  • Complementary selectivity to straight-chain alkyl phases
  • Exceptional peak shape for basic compounds under low- and high-pH conditions
  • Increased retention for acidic compounds at low pH

ACQUITY UPLC HSS Column Characteristics

ACQUITY UPLC HSS Column Characteristics

ACQUITY UPLC HSS T3 Columns
  • Ideal for the enhanced retention of polar and non-polar compounds
  • Compatible with 100% aqueous mobile phases
  • Mechanically stable at elevated pressures
ACQUITY UPLC HSS C18 Columns
  • General purpose silica-based C18 chemistry
  • Suitable for a broad range of compounds
  • Provides exceptional peak shapes and low pH stability
  • Delivers increased retention compared to hybrid organic/inorganic C18 columns
ACQUITY UPLC HSS C18 SB Columns
  • Low coverage silica-based C18 chemistry
  • Provides alternate selectivity for compounds impacted by silanophilic interactions
  • Increased silanol activity results in greater retention of basic compounds while reducing the retention of non-basic analytes
  • Provides exceptional peak shape and imparts Selectivity for Bases at low pH (SB)
ACQUITY UPLC HSS PFP Columns
  • Pentafluorophenyl (PFP) chemistry
  • Industry-leading reproducibility and peak shape
  • Ideally suited for planar aromatic compounds, positional isomers, halogenated compounds and polar analytes
ACQUITY UPLC HSS Cyano Columns
  • Provides low hydrophobicity and unique selectivity compared to straight-chain-alkyl columns
  • Ultra-stable retention
  • Exceptional peak shape and reproducibility under low- to mid-pH conditions
  • Compatible with both reversed-phase and normal-phase techniques

ACQUITY UPLC Application-Specific Column Characteristics

ACQUITY UPLC Application-Specific Column Characteristics

ACQUITY UPLC Peptide BEH C18 Columns
  • Suited for the reversed-phase analysis of hydrophobic and hydrophilic peptides at low and high pH
  • Outstanding peak capacity and peak shape in TFA or FA when compared to 100% silica based C18 columns
  • Two pore sizes (130 Å and 300 Å) for a wide range of peptides
ACQUITY UPLC Peptide CSH C18 Columns
  • Outstanding peak capacities with formic acid for MS-based applications
  • Excellent performance with TFA for optical based applications
  • Less dependence on TFA or FA to achieve optimal peak capacity
  • Accepts greater peptide mass loads than many competitive technologies for detection of low-level impurities
  • At low pH with the positive charge on CSH, you get less secondary interactions with the particle
ACQUITY UPLC Peptide HSS T3 Columns
  • Separations that require silica-based selectivity
  • Separations that necessitate increased peptide retention
  • Ideally suited for small, hydrophilic peptides
ACQUITY UPLC Protein SEC Columns
  • Sub-2-μm particle columns for UPLC separations (2.5 μm for 450 Å)
  • Pore size options include: 125 Å, 200 Å, and 450 Å
  • Specifically designed and QC tested with BEH125, BEH200, or BEH450 protein standards to help ensure batch-to-batch consistency
  • 10x faster than traditional HPLC-based SEC
ACQUITY UPLC Protein BEH C4 Columns
  • Separates proteins of various sizes, hydrophobicities, and isoelectric points
  • Tolerates extreme pH and temperature, and provides minimal secondary interactions
  • Improves sensitivity for phosphorylated proteins and low-level intact and subunit mAb analysis
  • High efficiency separations with 1.7 µm particles
ACQUITY UPLC Oligonucleotide Columns
  • Suited for the analysis of detritylated oligonucleotides using ion-pair, reversed-phase chromatography
ACQUITY UPLC Glycan Columns
  • Suited for the HILIC analysis of neutral and acidic glycans

Get superior peak shape for basic analytes

Reversed-phase bonded phases typically have poor peak shape for basic compounds when using formic acid, even at analytical mass loads. However, ACQUITY UPLC CSH Columns are the exception. These rugged UPLC Columns provide superior peak shape for basic analytes with formic acid or other low ionic-strength, acidic mobile phases. The controlled, low-level, positive surface charge bonded to the ethylene-bridged hybrid (BEH) particles provides excellent peak shape for bases—without the need for the use of ion-pairing reagents.


The ruggedness you want, the repeatability you need

ACQUITY UPLC BEH 1.7 μm fully porous columns provide superior analyte peak shape, efficiency, and chemical stability to any separation. ACQUITY UPLC BEH Columns are available in both reversed-phase and HILIC separation modes, with chemistries that provide selectivities for a wide range of compounds. With the ruggedness to operate at extreme pH conditions, ACQUITY UPLC BEH Columns enable separation scientists to use a wide pH range to influence retention, selectivity, and sensitivity for ionizable compounds.


Achieve flexibility in method development

Chromatographic laboratories need to quickly and easily develop robust methods that are compatible with all modern chromatographic detection modes and transferrable to laboratories and sites that operate different LC system platforms. With ACQUITY UPLC CSH and XSelect Columns, method development scientists in all application areas can achieve a wide range of selectivities without compromising performance across attributes, including superior peak shape for basic compounds, low column bleeds, excellent batch-to-batch reproducibility, and high efficiency.



Applications

Resources

Documents

Documents

No Results Found


Support

Support

User Manuals

No Results Found


Related

Achieve increases in sensitivity and analyte recovery while reducing column passivation time and mitigating unwanted analyte/surface interactions with ACQUITY Premier Columns.

Experience the ultimate in sensitivity, reproducibility, and speed. The ACQUITY Premier LC-MS provides the best sensitivity and peak shape for analytical separations.

Waters series of ion-exchange, size-exclusion, reversed-phase, hydrophobic-interaction, and hydrophilic-interaction chromatography columns offer you the diverse range of chromatographic selectivities needed to help characterize today's biotherapeutics and biosimilars. These columns support HPLC, UPLC, UHPLC, LC-MS analyses or lab-scale purification of oligonucleotides, amino acids, peptides, proteins and glycans.

Prolong analytical column lifetime while maintaining chromatographic performance with VanGuard Pre-columns and cartridges.

Offers and Discounts