2414 Refractive Index (RI) Detector

2414 Refractive Index (RI) Detector 

Reliable, repeatable analysis of non-absorbing components

Reliable, repeatable analysis of non-absorbing components

Designed to provide scientists with the highest sensitivity, stability, and reproducibility, the 2414 Refractive Index (RI) Detector is the ideal solution for the analysis and quantification of components with limited or no UV absorption, such as alcohols, sugars, saccharides, fatty acids, and polymers.

With the 2414 RI Detector, you can detect components without UV chromophores, achieve highly reproducible detection with a wide linear dynamic range, and attain stable thermal control with temperature equilibration of incoming solvent and a thermally isolated optics bench. The 2414 RI Detector completes a total sample-centric solution for many applications, including polymer analysis, quality control (QC) applications, preparative analysis, analytical analysis, and food applications.

Waters 2414 Refractive Index Detector. 2414 Refractive Index (RI) Detector

Specifications

Refractive index range

1.00 to 1.75 RIU

Measurement range

5.0 x 10-4 RIU to 7.0 x 10-9 RIU

Linear dynamic range

≤5.0% over ±5.0 x 10-4 RIU

Noise2

±1.5 x 10-9 RIU (2 s FTC Hamming 1.0 mL/min, 100% H2O)

±3.0 x 10-9 RIU 410/2410 emulation mode (1 s FTC (RC) 1.0 mL/min, 100% H2O)

Drift

2.0 x 10-7 RIU/hour

Filter time constant

0.0 to 5.0 s (Hamming)

0.0 to 10.0 s (RC)

Compatible flow rate range

0.1 to 10.0 mL/min

Attenuation settings

1 to 500 x 10-6 RIU

1 to 1024 maximum in emulation mode

Temperature control

Internal oven: 30 to 55 °C (86 to 131 °F), ±0.5 °C, settable 1 °C increments

One external column heater, steel: ambient to 150 °C (302 °F), ±1.0 °C, settable 1 °C increments

Flow cell

Fused quartz

Flow cell volume

10 μL

Flow cell pressure limit

≤100 psi

Light source

LED 870 nm

Wetted materials

316 stainless-steel, PTFE, PEEK, quartz

Power requirements

100 to 240 VAC

Line frequency

50 to 60 Hz

Power consumption

145 VA (nominal)

Inputs

Seven event inputs

Outputs

Three outputs (2 analog and 1 event)

Dimensions

Width: 34.3 cm (13.5 inches)

Height: 20.8 cm (8.2 inches)

Depth: 61.0 cm (24.0 inches)

Weight: 16.3 kg (36.0 pounds)

Operating temperature range

15 to 40 °C (59 to 104 °F)

Operating humidity range

20% to 80%, non-condensing

Audible noise

<58 dBA

Part Title

Part Number

2414 Refractive Index Detector for Alliance HPLC Systems

186241401

2414 Refractive Index Detector for ACQUITY Arc Systems

176017008

Column heating compartment

WAT038040

  1.  All performance specifications are measured following a warm-up period of 2 hours with ambient Δ T ≤±2.0 °C/hour
  2. ASTM E1303-95

Overview

  • Achieve unattended operation and simplify methods development with auto-zero, auto-purge, and LED-displayed diagnostic programming
  • Support sustainability goals with a convenient recycling valve to conserve mobile-phase
  • Get faster warm-up times and baseline stability with improved temperature controls
  • Support advanced fraction collection routines with necessary external output
  • Control columns from 30–150 °C for a broad range of applications with control of an external column heater

Recommended Use: To analyze and quantify components with limited or no UV absorption.

Features Header

Features Header






Accurate quantification in quality control

Many quality control applications are challenged by the need for accurate and repeatable quantification of components that do not have a UV chromophore. The wide, repeatable measurement range offered by the 2414 RI Detector makes it an excellent choice for such QC applications, enabling reliable and repeatable component quantification.


Highly repeatable polymer analysis

Polymer analysis by gel permeation chromatography (GPC) requires a highly repeatable system to obtain an accurate measurement of the molecular weight of the polymers. The 2414 RI Detector is designed to manage these stringent requirements for the chromatographic analysis of polymers. The thermal design of this detector delivers low noise and drift performance for accurate polymer measurements, even at lower concentrations. Combined with the highly repeatable solvent delivery of the Alliance HPLC System and the powerful data processing and reporting capabilities provided by the Empower Software GPC option, this system offers the ultimate solution for accurately and reproducibly determining the molecular weight distribution of a polymer.


Innovative thermodynamic management

Waters innovative counter-current heat exchanger quickly equilibrates temperature differences between the solvent stream entering and exiting the flow cell. This non-traditional heat exchanger prevents fluctuations in viscosity and refractive index, other than those changes caused by the sample itself. Consequently, the reproducibility is significantly enhanced with an optional, detector-controlled column heater, capable of stabilizing mobile phase viscosity prior to entering the detector.

The counter-current heat exchanger provides:

  • Improved temperature control
  • Faster warm-up times, baseline stability
  • Low baseline noise and drift

Flexible implementation

The 2414 RI Detector delivers a streamlined user experience, offering the flexibility to use it stand-alone or as part of any of Waters HPLC system solutions. Advanced fraction collection routines and control of external HPLC column ovens is supported by full module control in Empower Software. 

You can achieve simplified operation with:

  • Front panel control
  • Auto-purge that conveniently fills the reference flow cell with fresh mobile phase
  • User-accessible diagnostic functions, including automated noise and drift tests
  • Ease of use with simplified optics bench alignment, so routine maintenance is not required

Applications

Resources

Documents

Documents


Support

Support



Related

Providing versatile, dependable performance for analytical labs, the Alliance HPLC family meets the rigorous requirements of routine chromatography and the performance standards of new-product research and method development.

Count on Arc HPLC for high-efficiency separations and quality data that meet your regulatory requirements with confidence.

Get HPLC and UHPLC method compatibility at the flip of a switch with this versatile, modern LC system.

Confidently produce the most accurate, reliable, and reproducible data. The Arc Premier System provides right first time robust results from the very first injection, reliably and easily.

Offers and Discounts

Back To Top Back To Top
2414 Refractive Index (RI) Detector

The 2414 Refractive Index (RI) Detector sets a new standard for the analysis and quantification of non-absorbing components, offering unparalleled sensitivity, stability, and reproducibility. Tailored for scientists and researchers, this instrument excels in detecting substances that lack UV absorption—such as alcohols, sugars, saccharides, fatty acids, and polymers—providing a versatile solution across a broad spectrum of applications, including polymer analysis, quality control, preparative and analytical analysis, as well as food applications.

With an advanced thermal design and counter-current heat exchanger, the 2414 RI Detector ensures consistent temperature equilibration of the incoming solvent and maintains an isolated optics bench to prevent fluctuations in viscosity and refractive index. This meticulous control over thermal conditions results in low baseline noise and drift, enabling highly accurate and repeatable measurements even at lower concentrations.

Designed for ease of use, the 2414 RI Detector features front panel control for simplified operation, including auto-zero, auto-purge, and user-accessible diagnostics with LED-displayed programming. Its fast warm-up times and stable baseline enhance operational efficiency, while the recycling valve supports sustainability by conserving the mobile phase.

Integrating seamlessly into Waters HPLC systems with full module control via Empower Software, the detector supports advanced fraction collection and can control external column heaters for a wide range of temperatures, ensuring optimal performance for diverse analytical needs. Whether for quality control, polymer analysis, or any application requiring precise quantification of non-UV absorbing components, the 2414 RI Detector delivers exceptional accuracy, repeatability, and ease of use, making it an indispensable tool in any laboratory.