Chemistry |
C18 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
1 pH |
pH Range Max |
12 pH |
Endcapped |
Yes |
Particle Shape |
Spherical |
Particle Size |
1.7 - 5 µm |
Pore Size |
130 Å |
Format |
Method Transfer Kit |
Surface Area |
185 |
Particle Technology |
BEH |
USP Classification |
L1 |
Carbon Load |
18 % |
UNSPSC |
41115709 |
Brand |
ACQUITY UPLC, XBridge |
Product Type |
Column Kits |
Units per Package |
2 pk |
ACQUITY UPLC BEH Phenyl Column, 130Å, 1.7 µm, 3 mm X 50 mm, 1/pk
In addition to providing complementary selectivity to C18 stationary phases, particularly for polyaromatic compounds, the ACQUITY BEH Phenyl family of columns, including the Waters XBridge BEH Phenyl Column, also gives you the most chemically stable phenyl sorbent on the market. With the ACQUITY UPLC BEH Phenyl Column, you can get extremely minimal column bleed, lengthy column lives, and superb peak form.
For the analysis of analytes with pore sizes of 130Å and 1.7 µm, the Waters ACQUITY UPLC BEH Phenyl Column indicated above is the best option. You can use a wide pH stability range with the 3 mm I.D. column that is listed.
When compared to alternative phenyl columns that are currently on the market, the ACQUITY UPLC BEH Phenyl column offers exceptional batch-to-batch repeatability for all types of analytes. This is the outcome of thoroughly researched packaging materials that were created especially for use with the ACQUITY UPLC System. The tightest ISO 9001 requirements and exacting process control are used to produce these products. To ensure that you obtain lab equipment that provides outstanding reproducible performance, every batch of ACQUITY BEH packing material is also tested chromatographically with acidic, basic, and neutral analytes. The results are held to limited specification ranges. Each column is carefully evaluated before being given an eCord Intelligent Chip with a Performance Chromatogram and Certificate of Batch Analysis.
Use the ACQUITY UPLC BEH Phenyl Column to reduce the possibility of technique variation due to variances brought on by chromatographic media batch or column inconsistency. You can take advantage of the phenyl-hexyl ligand's trifunctional bonding to enjoy the best chemical stability, repeatability, and peak shape available for all analytes. The phenyl ligand has stationary phases that complement straight-chain alkyl phases in terms of selectivity, especially for compounds with aromaticity brought on by pi-pi interactions.
We recommend that you also learn more about and invest in the Reversed-Phase QC Reference Material.
Across What pH Range Does The ACQUITY UPLC BEH C18 Method Transfer Kit Operate?
The Waters ACQUITY UPLC BEH C18 Method Transfer Kit listed here is able to work well within the 1- 12 pH range.
What Is The Carbon Load Of The ACQUITY UPLC BEH C18 Method Transfer Kit?
For this particular ACQUITY UPLC BEH C18 Method Transfer Kit, the carbon load is 18%.