Chemistry |
HILIC |
Separation Mode |
Hydrophilic Interaction (HILIC) |
Particle Substrate |
Silica |
pH Range Min |
1 pH |
pH Range Max |
5 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
No |
Silanol Activity |
High |
Particle Shape |
Spherical |
Particle Size |
3 µm |
Endfitting Type |
Waters |
Pore Size |
100 Å |
Format |
VanGuard Cartridge |
Surface Area |
330 |
System |
HPLC |
Particle Technology |
Silica |
USP Classification |
L3 |
Inner Diameter |
3.9 mm |
Length |
5 mm |
UNSPSC |
41115709 |
Brand |
Atlantis |
Product Type |
Guards |
Units per Package |
3 pk |
Atlantis Silica HILIC VanGuard Cartridge, 100Å, 3 µm, 3.9 mm X 5 mm, 3/pk
By eliminating particle contamination from the mobile phase stream, Atlantis HILIC VanGuard Cartridges help to increase the lifespan and efficiency of analytical columns. All Atlantis HILIC analytical columns with 3.9 mm and 5 mm I.D. and 3 µm sorbent particles are protected by this cartridge. High organic mobile phases (>80% acetonitrile) are utilized in conjunction with Atlantis HILIC Silica columns and cartridges to retain analytes that are simply too polar for reverse-phase chromatography. When compared to conventional chromatographic reversed-phase methods, HILIC separation processes offer orthogonal analyte selectivity.
If you want to increase the lifespan of your analytical column, use the Atlantis HILIC VanGuard Cartridge. By clearing the mobile phase stream of chemical and particle pollution, the lab apparatus enhances the performance of the analytical column. The Atlantis HILIC Liquid Chromatography Columns are meant to be used in conjunction with the Waters Atlantis HILIC VanGuard Cartridges. The lab equipment has been optimized to work at the same level because the analytical column is constructed with the same packing materials.
The Atlantis HILIC VanGuard Cartridges are produced in compliance with the most exacting cGMP, ISO 9001 standards, much like all of Waters' equipment. Each component is examined and given the go-ahead before being shipped, guaranteeing that it will operate at optimal efficiency and boost the selectivity, sensitivity, and speed of your research. The manufacturing process is meticulously managed and tracked at every stage to guarantee that you receive only the best laboratory equipment.
To satisfy your lab requirements, you can shop for lab equipment on our website. You might also want to look at TruView LCMS Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk; The production and handling procedures used to create certified vials are tightly regulated. While low analyte adsorption is checked for using ACQUITY/MS/MS, cleanliness is checked using mass spectrometers.
What Causes My LC System To Constantly Shut Down?
To enhance system security, safeguard the columns and equipment, and assure system safety, HPLC pumps and systems come with an overpressure setting. The pump may stop working in order to safeguard the LC system if your system is operating at too low a setting or there is too much back pressure. Other factors could include the need for line cleaning or the removal of debris that has accumulated or crystallized and is obstructing or choking the system.