Take your separations​

Take your separations​

HPLC method development is not without its challenges. What happens when your favorite column struggles to achieve your peak shape, sensitivity, or reproducibility goals?

Whether you are working on:

  • Development or transfer of small molecule, protein, peptide, or glycan methods
  • Analysis or purification of biological, synthetic, or natural products
  • Core research in discovery functions
  • Support of developmental studies (GLP) or manufacturing monitoring (GMP)
  • Production monitoring (QA/QC) or purifications
Small Molecule Column Family on grey gradient background

Overview

Quickly achieve consistent results and better outcomes with MaxPeak Premier Columns. Featuring inert hardware called MaxPeak High Performance Surfaces (HPS) Technology, MaxPeak Premier Columns solve metal sensitivity related chromatographic challenges in UPLC, HPLC or Prep LC. Available from sub-2 µm to 5 µm particle sizes, fully-porous or solid-core, in analytical and preparative dimensions, you can choose the column configuration that meets your needs to eliminate doubt from your chromatographic separations.

What is NSA?

What is non-specific adsorption (NSA)? NSA refers to adsorption that was not intended between your sample and a surface. It is an undesired chemical interaction based predominantly on ionic interactions. Electron-rich compounds, such as those containing phosphate or carboxylate groups, organic acids, metal chelating compounds, and more can be lost to non-specific adsorption on metal surfaces.

Metal-sensitive compounds span a variety of compounds in biopharmaceutical, small molecule pharmaceutical, food/environmental, materials, and biomedical research applications including, organic acids, organophosphates, oligonucleotides, phosphopeptides, acidic peptides, acidic phospholipids, acidic glycans, nucleic acids, and metal chelating compounds.

These metal-sensitive analytes stick to the metal surface and cannot be removed. To prevent this problem, you either need to maintain the environment so that the interactions are not strong (through the use of complex mobile phases, conditioning, passivation, or other time-consuming and non-robust methods), or avoid the interaction altogether. MaxPeak High Performance Surfaces (HPS) Technology was specifically designed to prevent these undesired metal interactions within the flow path of the LC system.

The inert hardware is comprised of an inorganic-organic hybrid metal treatment that is non-reactive with compounds that interact with metal surfaces. The idea is to stop acidic groups from undergoing Lewis acid/base interactions with electron-deficient metal ions coming from the separation path in the workflow. MaxPeak Premier Columns feature this inert hardware, resulting in improved peak shape, improved recovery and sensitivity, superior reproducibility, and stable performance.

What's New

3.5 µm MaxPeak Premier HPLC Columns

3.5 µm MaxPeak Premier HPLC Columns

With expanded particle size options, you can now use MaxPeak Premier Columns to create and transfer methods from development to QC using any LC system. Eliminate doubt with consistent performance and reliable results right from the start. You can experience reduced risk and greater confidence in your data and decision-making with seamless scalability from small to large particle sizes.

3.5 and 5 µm MaxPeak Premier OBD Preparative Columns

3.5 and 5 µm MaxPeak Premier OBD Preparative Columns

Introducing the MaxPeak Premier OBD Preparative Column line for your scale-up needs in LC purification, offered in fully-porous 5 µm or a brand new 3.5 µm preparative particle size. Achieve predictable scale-up for challenging molecular targets prone to interactions, including peptides and oligos. Mitigate sample loss for critical isolations and reduce column conditioning.

CORTECS Premier 5 µm Columns

CORTECS Premier 5 µm Columns

If you love solid-core particles and want to eliminate doubt from your chromatography, CORTECS Premier Columns combine your favorite particle with MaxPeak High Performance Surfaces Technology.

With expanded particle size options, you can now experience the seamless scalability, speed, sensitivity, resolution, and confidence of CORTECS Premier Columns no matter what HPLC System you use.

1.7 and 2.5 µm MaxPeak Premier SEC Columns for Peptides and Proteins

1.7 and 2.5 µm MaxPeak Premier SEC Columns for Peptides and Proteins

The new MaxPeak Premier SEC 125Å Columns offer up to 30% improved resolution, 6x faster, and 7x solvent savings for insulin size-based separations. Reduce secondary interactions with 2.5x increase in High Molecular Weight Products (HMWPs) for GLP-1 receptor agonists. Available in 1.7 and 2.5 µm particle size for compatibility across HPLC, UHPLC and UPLC platforms.

2.5 & 3 µm GTxResolve Premier SEC Columns for AAVs, Nucleic Acids, and LNPs

2.5 & 3 µm GTxResolve Premier SEC Columns for AAVs, Nucleic Acids, and LNPs

With two particle size options, you can now use GTxResolve Premier SEC Columns to reduce column and system passivation through minimizing non-specific secondary interactions, thus enhancing peak shape, aggregate recovery, sensitivity and reproducibility, especially for metal-sensitive analytes, such as gene therapeutics.

XBridge XSelect Premier Column


Hit your targeted separation goals with MaxPeak Premier Columns — trusted columns that eliminate non-specific adsorption to improve data accuracy, reduce variability, and boost confidence in your separations.

Eliminate doubt with consistent performance every time.

A bow and arrow with a MaxPeak Premier column as the arrow

Get the control you need with MaxPeak Premier Columns — delivering predictable, reliable performance for routine chromatographic analyses. Manufactured to ISO-certified regulations, it’s the one you can trust when you need it most.

Eliminate doubt with the peak performance of your results. 


A conductor's hands in front of a music stand, conducting with a MaxPeak Premier Column

Trust in your analytical data with MaxPeak Premier Columns — knowing all peaks have been detected without time-consuming passivation compensating for non-specific absorption losses. Leaving you to develop, validate, transfer, and release your methods with confidence.

Eliminating doubt with reliable results from the start.


A golf ball on top of a tee made out of a MaxPeak Premier Column

Achieve reproducible chromatography with MaxPeak Premier Columns — saving you time and costs throughout the entire method lifecycle, with robust separations you can count on.

Eliminate doubt with quality control you can rely on, time and time again.



A white fence with the pickets made out of MaxPeak Premier Columns

Get faster results with MaxPeak Premier Columns — preventing time-consuming conditioning that comes with non-specific absorption, so you can achieve the speed you need to get your projects to market quickly.

Eliminate doubt with separations that run like clockwork.

A human hand holding a stopwatch, and one of the watch hands is a MaxPeak Premier Column

  • BEH (Ethylene Bridged Hybrid) columns — best in class stability at low and high pH
  • Compatible with a variety of mobile phase additives or buffers for faster method development
  • Universal columns ideal for a wide range of compounds
  • Multiple pore diameters available, optimized for a comprehensive selection of molecule sizes


  • Offers the widest selectivity range of base particles and ligands
  • Ideal for method scouting and development
  • Suited for all types of samples for HPLC & LC-MS analysis
  • CSH (Charged Surface Hybrid) columns — best peak shape for basic compounds at low pH
  • HSS (High Strength Silica) columns — increased retention for polar and non-polar compounds

  • Exceptional retention for polar compounds
  • Family including multiple separation modes, such as reversed-phase, mixed-mode, and HILIC
  • T3 provides balanced retention for broad analyte mixtures
  • Reversed-phase columns compatible with 100% aqueous mobile phases
  • Long column lifetimes with low mobile phase pH



  • Reduce non-specific adsorption losses due to metal interactions
  • Increase speed, sensitivity and resolution
  • Mass spectrometry (MS) compatible
  • Wide range of selectivities and pH range compatibility
  • Excellent batch to batch reproducibility
  • ACT Labeled

  • Highest resolution with increased column efficiency
  • Lower column backpressures enabling increased flowrates and throughput
  • Batch-to-batch reproducibility for expected results
  • Excellent low pH stability for longer column lifetimes
  • Solid-core technology

Not sure where to start?


See and do more with MaxPeak Premier Columns

See and do more with MaxPeak Premier Columns
  • 10x improvement in assay precision and reproducibility
  • Up to 5x increase in sensitivity
  • 30% faster data processing for metal sensitive compounds

Say farewell to column conditioning

Say farewell to column conditioning

Out-of-the-box performance for analytes containing:

  • Acids
  • Phosphates
  • Chelating functionalities
ACQUITY Premier Columns Family

Resources


MaxPeak Premier Columns continue to raise the bar in the scientific world, setting a whole new standard in testing. But don’t just take our word for it. See what researchers all over the world are saying about the difference.

"Worth using Waters Premier columns." — Nobel llac
"Astonishing separation with maximal resolution and confidence." — Chromatography Evolution
"Great and reliable results." — University Of Nicosia
"Smooth method transfer and significantly lower carry-over for sticky peptides." — Nutrilab BV
"Significantly lower carry-over when using the Premier column." — Charles River Laboratories
"Strongly improved peak shape in comparison to non-premier columns." — University of Innsbruck
"Superior peak shape compared to all other columns in our laboratory." — UiT The Arctic University of Norway

Shop Now

Explore MaxPeak Premier Columns today to help your lab eliminate doubt and ensure confidence in your separations.

Abstract hexagonal structure backgrouond
Back To Top Back To Top