Building on industry-standard performance and reliability, the Alliance HPLC System provides the capabilities to meet today’s business challenges. With its proven performance history, the Alliance HPLC is the industry’s analytical HPLC system of choice, ideally suited for methods development and routine analysis.

Alliance HPLC System Alliance HPLC System

Specifications

Maximum operating pressure  

5,000 psi

Front panel display

Easy to use control panel

Mobile phases

Up to 4 with Auto-Blend Technology

Flow rate range  

Up to 10 mL/min

Sample carryover  

≤0.0025% (Caffeine) under specified conditions

Sample compartment  

4–40 °C

Pump options  

Quaternary

Solvent conditioning  

Vacuum Degas

Column capacity  

Standard up to 3 columns

Maximum sample capacity  

120

Detector options   

Tunable UV

Photo Diode Array

Fluorescence

Refractive Index

Evaporative Light Scattering

Electrochemical

Conductivity

Mass Spectrometry

External control   

Empower Software

MassLynx Software

Physical specifications

Width: 45.7 cm (18.0 in.) or 58.4 cm (23.0 in.) with column heater

Height: 57.1 cm (22.5 in.)

Depth: 57.1 cm (22.5 in.) or 64.8 cm (25.5 in.) with sample heater/cooler

Overview

  • Time-tested, dependable, and robust workhorse for your HPLC separations
  • Integrated solvent and sample management with consistent system-to-system performance and high reproducibility
  • Simplify your daily LC system start-up with advanced software functionality

Recommended Use: For standard HPLC workflows where consistency and compliance are the highest priorities.


Excellence through the years

The consistency of the Alliance HPLC System gives you exceptional confidence in your analytical results, day-to-day and year-to-year. Get accurate and reproducible results with Waters flagship HPLC technology, which provides consistent and reliable performance. Whether your Alliance HPLC System is newly manufactured, or you're working on one that is several years old, the Alliance HPLC System is a time-tested, dependable, and robust workhorse for your HPLC separations.


Performance that exceeds your method requirements

The Alliance HPLC System ensures the reliability of your results via high injection precision and repeatable and accurate flow rates, resulting in easy peak identification, precise quantification, and exceptional retention time repeatability.

The integrated solvent delivery system features quaternary blending with a fixed delay volume for consistent and predictable results, regardless of system back pressure. The sample managers’ flexible injection capabilities cover a wide injection volume range (up to 2 mL) with excellent carryover performance, typically below 0.005%.


Advancements in column chemistry and mass detection

The Alliance HPLC can leverage smaller particle size column chemistry to improve your laboratory's efficiency. With CORTECS 2.7µm particle size columns, your lab will benefit from improvements in resolution and faster run times when transferring from a 5µm size particle chemistry.

Further increase confidence in your data by adding mass confirmation with the ACQUITY QDa Detector, which is as simple to use and can easily integrate into your existing workflow. Analysis in Empower 3 Software combines the data from the UV/Vis and mass spectrometry (MS) peaks to give mass information to each peak in the separation.


Features and benefits

  • Quaternary solvent blending. Support isocratic and gradient applications with 11 unique gradient profile curves and blend up to 4 solvents in any proportion with Auto-Blend Technology. Compatible with solvent types such as reversed-phase, normal-phase, GPC, SEC, and IEX.
  • Advanced solvent delivery capabilities. Serial flow path with pulse-free solvent delivery without the use of dampeners. Online solvent degassing and automated solvent compressibility compensation for accurate flow. Integrated seal wash for robust operation with all solvent types is standard.
  • Optional, temperature-controlled environment. House up to 120 vials in an optional, temperature-controlled environment. Achieve low carryover with active and user programmable needle wash. Variable injection volumes from 0.1 to 100 μL standard, and up to 2 mL optional. Support STAT samples and auto-addition.
  • Detection and column options. Get optional column heating, heating/cooling, or column switching capabilities. Detection capabilities include photodiode array, UV/Vis, fluorescence (FLR), refractive index (RI), evaporative light scattering (ELS), electrochemical, conductivity, and mass detection.
  • Intuitive interface and software. Get instant access to system settings through the large LCD screen with simplified daily set-up with SystemPREP. Supports Empower, MassLynx, and 3rd party software packages.
  • Compliance-ready. Supports Waters Empower-based automated system qualification tool (SQT), minimizing the time and cost of annual qualification with standards like GMP, GLP, ISO 17025, and USP <1058>.

Resources

Documents

Documents


Support

Support



Related

ACQUITY QDa II Detector is a mass detector built around the needs of analytical scientists for chromatographic analysis. Robust, reliable, and requiring no sample adjustments, it integrates with your current LC, ACQUITY UPLC, UPC2, and purification systems.

HPLC/UHPLC optical detectors provide additional analytical detail about your samples and pair with accessories like flow cells and nebulizers to obtain more information per run.

Industry-leading HPLC columns supported by innovative chemistries and technologies. Maximize your laboratory performance by optimizing method development or purification.

Deliver samples that are reproducible, yield high recovery and are free of interferences with Waters Sample Preparation Products. Proven sample preparation tools for your LC-MS and GC-MS analysis.
Back To Top Back To Top

FAQs about Alliance HPLC System

What is the Alliance HPLC System?
The Alliance HPLC System is a high-performance liquid chromatography system designed to provide reliable, reproducible results for a wide range of applications. It features a modular design that allows for easy customization and scalability, as well as advanced software and hardware features for maximum efficiency.

What are the benefits of using the Alliance HPLC System?
The Alliance HPLC System offers a number of benefits, including improved accuracy and reproducibility, increased throughput, and reduced maintenance costs. It also features a modular design that allows for easy customization and scalability, as well as advanced software and hardware features for maximum efficiency.

What types of applications can the Alliance HPLC System be used for?
The Alliance HPLC System can be used for a wide range of applications, including pharmaceutical analysis, environmental analysis, food and beverage analysis, and more.

What type of support is available for the Alliance HPLC System?
Waters provides comprehensive support for the Alliance HPLC System, including technical support, training, and software updates.

How much does the Alliance HPLC System cost?
The cost of the Alliance HPLC System varies depending on the configuration and features selected. Please contact Waters for more information.

What is the Waters Alliance HPLC System used for?
The Waters Alliance HPLC System is used in laboratories to separate, identify, and quantify chemical compounds in complex mixtures. It"s commonly employed in pharmaceutical research to analyze drug purity, potency, and stability. Environmental labs use it to detect contaminants in water, soil, and air samples.
The system is also valuable in food and beverage testing, ensuring product safety and quality by analyzing additives, preservatives, and potential contaminants. Its versatility and precision make it a trusted tool across various industries where accurate chemical analysis is essential.

How do I clean the Alliance HPLC System after use?
Cleaning the Alliance HPLC System after use is crucial to maintaining its performance and preventing contamination. Begin by flushing the system with a solvent that is compatible with the mobile phase used in your analysis. This removes any residual sample or buffer. For thorough cleaning, use a sequence of solvents starting with water, followed by a stronger solvent like acetonitrile or methanol, and finally, rinse with water again.
Always clean the column separately according to the instructions provided by Waters. Regular cleaning after each use will help keep the system in optimal condition and extend its lifespan.

Can I use the Alliance HPLC System with different types of samples?
Yes, the Alliance HPLC System is versatile and can be used with various types of samples, including liquids, solids, and gases. It"s commonly employed for the analysis of small molecules, peptides, proteins, and polymers. The system"s flexibility allows it to handle complex mixtures, making it suitable for applications in pharmaceuticals, environmental testing, food and beverage analysis, and more.
However, samples must be properly prepared and dissolved in a suitable solvent before injection into the system. Following appropriate sample preparation techniques ensures accurate and reliable results across different sample types.