Chemistry |
HILIC |
Separation Mode |
Hydrophilic Interaction (HILIC) |
Particle Substrate |
Silica |
pH Range Min |
1 pH |
pH Range Max |
5 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
No |
Silanol Activity |
High |
Particle Shape |
Spherical |
Particle Size |
3 µm |
Endfitting Type |
Waters |
Pore Size |
100 Å |
Format |
VanGuard Cartridge |
Surface Area |
330 |
System |
HPLC |
Particle Technology |
Silica |
USP Classification |
L3 |
Inner Diameter |
2.1 mm |
Length |
5 mm |
UNSPSC |
41115709 |
Brand |
Atlantis |
Product Type |
Guards |
Units per Package |
3 pk |
Atlantis Silica HILIC VanGuard Cartridge, 100Å, 3 µm, 2.1 mm X 5 mm, 3/pk
For reversed-phase liquid chromatography, the Waters Atlantis Silica HILIC VanGuard Cartridge is intended to work with Atlantis Silica HILIC Columns. Since the analytical column is constructed utilizing the same packing materials, the lab equipment has been tuned to offer the same degree of performance. An Atlantis Silica HILIC Column's inlet side can be immediately linked to the VanGuard Cartridge, which is a single item.
The Atlantis Silica HILIC VanGuard Cartridge, like all of the lab equipment that Waters produces, is made in accordance with the strictest cGMP, ISO 9001 guidelines. Each piece is tested and certified for use, ensuring that it will perform at its peak level and improve the selectivity, sensitivity, and speed of your analysis. To guarantee that you only receive the highest caliber lab equipment, every stage of the manufacturing process is meticulously controlled and observed.
To increase the lifespan of your analytical column, use the Atlantis Silica HILIC VanGuard Cartridge. The lab equipment enhances the performance of the analytical column by eliminating chemical and particle pollution from the mobile phase stream. The protection provided by this cartridge extends to all 2.1 mm and 3.0 mm I.D. 3 µm sorbent particles present in Atlantis Silica HILIC analytical columns. Your UPLC analytical columns will survive longer with the use of the Atlantis Silica HILIC VanGuard Cartridge without sacrificing their chromatographic analytical performance. The columns' UPLC, UHPLC, and HPLC separation efficacy are maintained by eliminating undesirable contaminants from them.
You may also be interested in the LCGC Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk. These vials are made to meet the requirements of LC/GC certification and to take into account all aspects of use, including volatility, tray design, and needle design. An HPLC test is performed on every vial to check for traces of compounds introduced during processing and manufacture. The improved resealing properties of the PTFE/Silicone septum will help with repeated injections and sample storage. These vials have PTFE chemical resistance up until rupture, at which point the silicone chemical compatibility of the septum kicks in. This permits operating temperatures between -40 C and 200 C.
Is There A pH Limit For The Atlantis Silica HILIC VanGuard Cartridge?
The Atlantis Silica HILIC VanGuard Cartridge listed here is able to work across the 1-5 pH range.
What Is The Recommended Maximum Pressure For The Atlantis Silica HILIC VanGuard Cartridge?
This particular Atlantis Silica HILIC VanGuard Cartridge has been designed to sustain a maximum of up to 18000 psi (1240 Bar) pressure.