Chemistry |
C8 |
Separation Mode |
Reversed Phase |
Particle Substrate |
Hybrid |
pH Range Min |
2 pH |
pH Range Max |
12 pH |
Maximum Pressure |
18000 psi (1240 Bar) |
Endcapped |
Yes |
Bonding Technology |
Shield RP8 |
Silanol Activity |
Low |
Particle Shape |
Spherical |
Particle Size |
5 µm |
Endfitting Type |
Waters |
Pore Size |
125 Å |
Format |
VanGuard Cartridge |
Surface Area |
175 |
System |
HPLC |
USP Classification |
L7 |
Inner Diameter |
3.9 mm |
Length |
5 mm |
Carbon Load |
14 % |
UNSPSC |
41115709 |
Brand |
XTerra |
Product Type |
Guards |
Units per Package |
3 pk |
XTerra Shield RP8 VanGuard Cartridge, 125Å, 5 µm, 3.9 mm X 5 mm, 3/pk
Utilize the XTerra Shield RP8 VanGuard Cartridge to get around the main drawbacks of silica-based reversed-phase packing materials. The lab apparatus makes use of the proprietary organic/inorganic hybrid particle technology (HPT) from Waters, which was created expressly to address the hydrolytic instability of conventional silica columns at high pH. By eliminating particle pollution from the mobile phase stream, XTerra Shield RP8 VanGuard Cartridges are used to increase analytical column lifetime and performance. All 3.9 mm and 4.6 mm I.D. XTerra Shield RP8 analytical columns with 5 µm sorbent particles are well-protected by this cartridge.
Benefit from the special advantages of the XTerra Shield RP8 VanGuard Cartridge by including it in your collection of lab supplies. Important benefits of the VanGuard Cartridge include its mechanical toughness, extremely spherical shape, purity, pore size, surface area, and capacity to customize particle size, pore size, surface area, and surface chemistry. Utilizing conventional bonding agents enables this. The XTerra Shield RP8 VanGuard Cartridge additionally supports the general-purpose XTerra Shield RP8 Column by providing peak shape performance for extremely basic chemicals while retaining high separation efficiency.
The XTerra Shield RP8 VanGuard Cartridge is compatible with the XTerra Shield RP8 Column and is made from high purity methyl hybrid material, which is generated using a process similar to that of high-purity silica. The XTerra substance is created from the combined condensation of two high purity monomers as opposed to one, which is a significant distinction. Tetraethoxysilane (TEOS) and methyltriethoxysilane are used in the hybrid particle synthesis process to create the XTerra column (MTEOS). Additionally, the VanGuard Cartridges are produced in accordance with ISO 9001 guidelines, guaranteeing that every stage is carried out to the highest standards and tightest tolerances.
In addition to connecting with a member of our global support staff who can help you with any inquiries or worries you might have, you will be able to shop for lab equipment in accordance with your laboratory needs. You should also review LCMS Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk; All Waters LCMS Certified vials are produced following tightly controlled manufacturing processes and handling procedures. They are tested with mass spectrometers and come packaged with a certificate of analysis showing the reference and vial scan for the manufacturing lot.