Separation Mode |
HILIC |
Detection Method |
FLR |
Formulation |
Solid |
Storage Condition |
-20C +/- 10C (Freezer) |
System Type |
LC |
Shelf Life |
36 Months |
Shipping Condition |
Ambient |
Mass |
Released N-glycans from 30ug of Fetuin |
Type |
Reference |
UNSPSC |
41116107 |
Application |
Glycan |
Brand |
Rapifluor-MS |
Product Type |
Standards |
Units per Package |
1 pk |
RapiFluor-MS Sialylated Glycan Performance Test Standard
The RapiFluor-MS Sialylated Glycan Performance Test Standard is designed to be used as a proficiency or system suitability test standard, particularly for non-mAb clients, to address the chromatographic gap for highly sialylated glycans that 186007983 does not cover because to its IgG basis. This standard contains around 30 μg of fetal bovine serum Fetuin or about 400 pmoles of RapiFluor-MS tagged, released N-glycans.
The RapiFluor-MS Sialylated Glycan Performance Test Standard, similar to all Waters products, is produced in the Waters chromatography chemistry manufacturing plant under the most stringent cGMP, ISO 9002 requirements. Silica-based and polymeric chromatography materials are manufactured and packed into columns and solid-phase extraction devices at the manufacturing site. This ensures that you get high-quality lab equipment that produces consistent and trustworthy findings.
The RapiFluor-MS Sialylated Glycan Performance Test Standard is recommended to be stored in a -20C +/- 10C (Freezer) environment and will provide you with a shelf life of 36 months. You can shop for lab equipment and explore our comprehensive selection of a number of applications by browsing our catalog or visiting our website. Please contact a member of our global team if you have any questions, concerns, or require any guidance in lab equipment selection, and we will gladly assist you.
You might also be interested in the Waters Carbamate Analysis Kit, which comprises a Waters Carbamate column, Oasis HLB cartridges, vials, and Reference Standards. These items, developed for use with EPA Method 531.2, simplify your analysis while enhancing your confidence in the results. Carbamate Columns are designed and tested for high sensitivity and excellent resolution. This column is specified as the primary column for EPA Method 531.2. Oasis HLB Cartridges are for sample cleanup and concentration to ensure maximum sensitivity. Vials are certified to be clean and free of background contamination in order to provide optimized analysis.
What Should I Do If My Chromatography Changes?
Chromatography columns commonly undergo changes due to column degradation caused by the solution or the presence of trapped substances that require removal. To prevent degradation, it is important to monitor and adjust the solution pH and pressure in the system when using a silica column. To remove bound organics, we suggest washing with solvents that have the same polarity as the column. Additionally, for ion-exchange columns, a high-concentration salt washout can effectively eliminate the majority of impurities.